6.10
Limit switch approach bar
6.10.1
Landing limit switch, approach bar
Assembly
Place the landing limit switch approach bar (1)
into the mast section.
Place the landing limit switch approach bar
(1) at the centre hole (2) on the top
crossbeam of the mast section and align
vertically.
Firmly attach the landing limit switch
approach bar (1) at the rear on both
crossbeams of the mast section.
WARNING
Danger to life
During
operation
, the max. loading height above the last anchor is
7.5
m
.
The limit switch approach bar of the uppermost landing must be set
correspondingly low.
Operation without a correctly installed limit switch approach bar is
prohibited.
Before the initial intended use, the
EMERGENCY limit switch
approach bar
must be installed in accordance with the following
information.
2