Electrical connected loads
GEDA
®
3700 Z/ZP
Assembly Instructions
Page 16 of 60
ML034 GB 2017 / 11
5
Electrical connected loads
Mains connection (refer to the
nameplate)
400 V / 50 Hz / 3 Ph/PE
480 V / 60 Hz / 3 Ph/PE
Mains fuse
3 x 63 A slow-to-blow
Protection class
IP 54 (NEMA 3)
Connection to the building site distributor in accordance with
IEC 60439-4:2005
The cables provided by the customer must be designed so that:
•
They correspond to the connected load of the machine.
•
No interference voltages or interference frequencies occur.
•
The response behaviour of the safety equipment meets the relevant
legal requirements.
The necessary cable cross-section must be determined while taking into
account the requisite installation type according to DIN VDE 0298
Section 4 and DIN VDE 0100 Section 430. Country-specific rules must be
observed.
WARNING
The equipotential bonding for the transport platform must be
connected to the primary equipotential bonding of the building!
The machine must be integrated into the lightning protection concept
of the building.