Fig.46
®
Done.
Adjusting the proximity switch holder
Carry out the following steps:
1.
Screw the adjusting screw (6) into the proximity switch holder down to the
cleaning connection (7).
Fig.47
Fig.48
2.
By slightly slackening the countersunk screw, position the proximity switch
holder in the slot in the lantern so that the point of the adjusting screw (6)
rests on the shoulder of the cleaning connection in the direction of the
actuator (A).
3.
Fix the proximity switch holder in position with the countersunk screw.
®
Done.
Fitting the proximity switch
Carry out the following steps:
1.
Remove the adjusting screw.
2.
Screw proximity switch M12 (8) into the proximity switch holder until the
cleaning connection is reached.
Start-up
Adjust the proximity switch in the lantern - for unbalanced double disks of the valves D, R, Y, B, T_R