4.
Align the pneumatic and electrical connections in accordance with the valve
block configuration.
5.
Close the air connection Y1 with a sealing plug (23) since the control top
T.VIS A-15 has an inner air duct.
Fig.33
6.
Perform commissioning, see Chapter 6, Page 41 and Chapter 7, Page 67.
®
Done.
6.6.6
Mounting to ECOVENT Valves N_ECO and W_ECO
Requirement:
•
Pay attention not to kink the air hoses when mounting the control top.
Carry out the following steps:
1.
Complete the T.VIS mounting base (198) with O-rings (29, 101) and a plain
bearing (202).
Fig.34
Assembly and installation
Mounting the control top to different valves
430BAL010699EN_6
60
17.03.2022
Содержание T.VIS A-15