Fig.40
Requirement:
•
Pay attention not to kink the air hoses when mounting the control top.
Carry out the following steps:
1.
Screw the switch bar (1) into the piston rod A4.1 and tighten with open-end
wrench SW13 at (1.1), torque 2 Nm.
2.
2. Fit the control top (B) over the switch bar (1) and on the actuator (A.4).
3.
3. Tighten the clamp connection (15) and screws (39) to a torque of 1 Nm.
4.
4. Align the pneumatic and electrical connections in accordance with the valve
block configuration.
!
Internal air guiding is not possible on these valve types. Therefore connect
the air connection (Y1) on the control top and the connection (A.4.2) on the
actuator to the air hose (L).
5.
Perform commissioning, see Chapter 6, Page 41 and Chapter 7, Page 67.
®
Done.
6.6.11 Fitting to an ASEPTOMAG Valve
Requirement:
•
Pay attention not to kink the air hoses when mounting the control top.
Carry out the following steps:
1.
Place the T.VIS adapter plate (M), with O-rings (M1), on the actuator (A.4)
and secure it with four M5 screws (M.2).
Assembly and installation
Mounting the control top to different valves
430BAL010699EN_6
17.03.2022
65
Содержание T.VIS A-15
Страница 6: ...430BAL010699EN_6 6 17 03 2022...