* Assignment for colour variant green, see Section 6.5.2, Page 53.
Technical data: outputs
Bit
Function
Signal
DO0
Activation of solenoid
valve Y1
1 = solenoid valve
activated
0 = solenoid valve not
activated
DO1
Activation of solenoid
valve Y2
1 = solenoid valve
activated
0 = solenoid valve not
activated
DO2
Activation of solenoid
valve Y3
1 = solenoid valve
activated
0 = solenoid valve not
activated
DO3
not assigned
Technical data: LED indicators for module and network status
Designation
Description
Green
Operation
Flashing green
Communication time-out or module
faulty
Flashing red
Power-up test
Flashing orange
Baud rate detection
Red
Communication not possible
DIP switches
Fig.9
Switches 1 and 2 = baud rate
DIP 1
DIP 2
Baud rate
OFF
OFF
125 kBaud
ON
OFF
250 kBaud
Technical data
DeviceNet specifications
430BAL010699EN_6
17.03.2022
37