Fig.26
6.
Perform commissioning, see Chapter 6, Page 41 and Chapter 7, Page 67.
®
Done.
6.6.2
Fitting to FLOWVENT Valve
Requirement:
•
Pay attention not to kink the air hoses when mounting the control top.
Fig.27
Carry out the following steps:
1.
Insert the O-ring (F1) into the lower O-ring groove of the installation base (F).
2.
Lightly grease the O-ring (F1) and the inner thread of the installation base (F)
and then screw the installation base onto the actuator and tighten using a pin-
face spanner and a torque of 20 Nm. When setting the torque heed the
correction factor of the plug tool. If the plug tool (408-451) is used, the torque
to be set is 15 Nm.
3.
Screw switch bar (1) into the actuator and tighten with SW 13, torque 2 Nm
(1.4 lbft).
Assembly and installation
Mounting the control top to different valves
430BAL010699EN_6