4.
Screw the switch bar (1) together with switch bar (11) into the actuator, torque
2 Nm.
5.
Fit the control top (B) over the switch bar (1) and on the actuator.
6.
Tighten the clamps (15) and screws (39) to a torque of 1 Nm (0.7 lbft).
7.
Align the pneumatic and electrical connections in accordance with the valve
block configuration.
8.
Close the air connection Y1 with a sealing plug (23) since the control top
T.VIS A-15 has an inner air duct.
Fig.31
9.
Perform commissioning, see Chapter 6, Page 41 and Chapter 7, Page 67.
®
Done.
6.6.5
Mounting to a Butterfly Valve T-smart 7 and a Mixproof Butterfly Valve T-smart 9
Requirement:
•
Pay attention not to kink the air hoses when mounting the control top.
Carry out the following steps:
1.
Screw the switch bar (240) into the actuator and secure it at a torque of 22
Nm (16 lbft).
Fig.32
2.
Fit the control top (B) over the switch bar (240) and on the actuator.
3.
Tighten the clamps (15) and screws (39) to a torque of 1 Nm (0.7 lbft).
Assembly and installation
Mounting the control top to different valves
430BAL010699EN_6
17.03.2022
59
Содержание T.VIS A-15