Technical data: inputs as seen from the IO-Link
Bit
Function
Signal
DIB X
DI0*
(single-seated
valves / disk valves)
S1
Feedback
1 = valve in non-
actuated position
Main stroke
0 = valve outside
tolerance for non-
actuated position
(double-seated
valves)
S1
Feedback
1 = valve closed
Valve disk
0 = valve outside
tolerance
DI1*
S2
Feedback
1 = valve in actuated
position
Main stroke
0 = valve outside
tolerance for
actuated position
DI2
S3
Feedback
1 = double-disk
closed
Double-disk
0 = double-disk not
closed or no external
sensor present
DI3
(double-seated
valves)
S4
Feedback
1 = valve in non-
actuated position
Main stroke
0= valve disk
and
double-disk not
closed
DI4
…
DI7
not assigned
DIB X +1
DI0
PV Y1 on
1 = solenoid valve
activated
Technical data
IO-Link specifications
430BAL010699EN_6
17.03.2022
29