Installation
Installation of the evacuation line
2007-9015-001
03-2014
Space the anodes along the evacuation line as shown.
Anodes
Activation of the sacrificial anode
Attention!
Discard any plastic film that may have been wrapped around the
anode cardboard tube for handling. Do not remove the plastic caps
from the cardboard tube.
The dry conductive powder in the cardboard tube must be saturated with water
before burying the sacrificial anode.
● Using a knife, make a cut in the plastic cap and fill the tube with water.
● The cardboard will disintegrate within months and the natural moisture of the
soil will keep the conductive powder humidified through the years.
Legend:
1
Anode copper wire AWG #12/7
2
Cut in plastic cap
3
High purity magnesium bar*
4
Plastic cap
5
Conductive powder
6
Insulated welded connection
7
Galvanized steel sheet
8
Cardboard tube
* This bar will disintegrate slowly over several years.