Maintenance
Scheduled maintenance responsibilities
2007-9015-001
03-2014
9.3.3
Every 100 hours
Check the hydraulic power unit oil level
Note!
Use hydraulic oil.
Refer to section on Lubricant specifications.
● Ensure the oil reservoir of the
hydraulic power unit is 2/3 full.
● If the fluid level drops, check the
system for leaks, resolve the
problem and add oil as needed.
● Never let the fluid level drop to where
it isn't visible in the sight gauge.
● Look for changes in the appearance
of the fluid i.e. dark, cloudy, etc...
Oil sight
gauge
Attention!
Wipe up any oil spills. Safely dispose of used oil by following local
and/or state regulations concerning the proper handling of dangerous
goods.
9.3.4
Every 3 month or sooner
Clean out the top of piston and replace oil
Note!
Use biodegradable oil.
Refer to section on Lubricant specifications.
● Remove dirty oil from the surface
and clean it.
● Pour 2” [5cm] of biodegradable oil
above pump piston.
2” [5 cm]