Installation
Installation of the evacuation line
2007-9015-001
03-2014
● The air flush valve must be
connected to an air tank.
● All connections to the valves on the
air riser cap should be made with
flexible hoses to allow removal of the
cap.
Gate valve
6” [152 mm]
Relief valve
Flush valve
● If the air flush riser is installed
indoors the relief valve must
plumbed to exhaust manure gases
outdoors.
Relief valve
Air tank requirements
Note!
To flush the full length of evacuation line, it needs a certain volume of
compressed air. Refer to the table below to find appropriate air tank
size required to flush the full length of evacuation line.
12 3/4” [315 mm] evacuation line
Air
Pressure
Length of evacuation line.
100'
30 m
150'
46 m
200'
60 m
250'
76 m
300'
91 m
350'
107 m
400'
122 m
450'
137 m
500'
152 m
550'
168 m
600'
183 m
Minimum size of air tank
125 psi
[8.6 bar]
175g
665 L
265 g
998 L
350 g
1334 L
440 g
1667 L
530 g
2000 L
615 g
2332 L
705 g
2665 L
790 g
2998 L
880 g
3330 L
970 g
3663 L
1055 g
3999 L
100 psi
[6.9 bar]
220 g
832 L
330 g
1247 L
440 g
1667 L
550 g
2083 L
660 g
2499 L
770 g
2914 L
880 g
3330 L
990 g
3746 L
75 psi
[5.2 bar]
295 g
1111 L
440 g
1667 L
590 g
2223 L
735 g
2775 L
880 g
3330 L
1025 g
3886 L