Maintenance
Scheduled maintenance responsibilities
2007-9015-001
03-2014
9.3.5
Every 3000 hours or yearly
Change oil of hydraulic power unit
Caution!
Ball valves under the reservoir can only be closed for servicing when
the power supply have been turned off. When servicing is done,
always keep these 2 ball valves opened to avoid damage and/or
injuries.
Note!
Use hydraulic oil.
Refer to section on Lubricant specifications.
● Place a large container under the oil
filter in order to recuperate oil. (more
than 16 US gallons [60 litres])
● Close 2 ball valves under the power
unit reservoir.(A)
● Remove the oil filter.(C)
● Open the cap on top of reservoir.(B)
● Open both ball valves to completely
drain the oil.(A)
● Clean the oil filter receptacle.
● Using hydraulic oil, lubricate the seal
of the new filter and install it on its
receptacle.
● Pour 16 US gallons [60 litres] of
hydraulic oil in the reservoir making
sure is 2/3 full.
● Reinstall the top cap.(B)
B
A
A
C
Pos.
Part-No.
Description
1
2007-3400-130
Hydraulic power unit oil filter