Description
Main View
2007-9015-001
03-2014
Air flush
In sand bedding operation, the air flush option is mandatory to push the sand
out of the evacuation line.
The evacuation line should be flushed periodically using air pressure only
and/or air pressure and a straw bullet.
If the top of the manure reservoir is higher than the cap on the air flush riser pipe,
a gate valve must be installed to prevent manure flow into the air line.
1
5
6
2
3
4
Legend:
1
Air valve 2” [50 mm]
2
Relief valve ¼” [6 mm]
3
Cap 6” [150 mm]
4
Gate valve 6” [150 mm]
5
Air flush riser
6
Flow direction
Sacrificial anode
Connected to buried steel evacuation lines, it protects them against corrosion.
Legend:
1
Anode copper wire AWG #12/7
2
Cut in plastic cap*
3
High purity magnesium bar
4
Plastic cap
5
Conductive powder
6
Insulated welded connection
7
Galvanized steel sheet
8
Cardboard tube
* Cut is made at time of installation to fill the tube with water for activation.