NX-4V2 Control
31
LOC
PG
DESCRIPTION
DEFAULT
PROGRAM DATA
L
42
19 GO TO PROGRAM CODE
9-7-1-3-0-0
_ _ _ _ _ _
43
19
GO TO PROGRAM CODE & AUTHORIZATION
Segment 1 (Circle numbers to program)
1
=
Reserved.
2 = Enables "Go To Program Code" as an arm only code.
3 = Enables "Go To Program Code" as an arm only after closing.
4 = Enables "Go To Program Code" as a master arm/disarm code (can change user codes)
5 = Enables "Go To Program Code" as an arm/disarm code.
6 = Enables "Go To Program Code" to bypass zones.
7 = Enables "Go To Program Code" opening and closing reports.
8 = Reserved.
Segment 2 Reserved
L
44
19 DURESS CODE
15-15-15-15-15-15
_ _ _ _ _ _
45 19 RESERVED
46
20
AUXILIARY OUTPUTS 1-2 SPECIAL TIMING
Segments (Aux Out)
1
2
1 = Aux output timed in minutes.
2 = Aux output to latch.
3 =
Aux output to stop timing upon user code entry.
4 = Aux output to activate only between closing & opening time.
5 = Aux output to activate only between opening & closing time.
6 = Invert auxiliary output (0 Volts going to 12V when activated).
7 = Reserved
8 = Reserved
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
47
20
AUXILIARY OUTPUT #1, EVENT & TIME
Segment 1: Event number for output # 1
0=Burglary alarm
Segment 2: Timing for output # 1
10 seconds
48
20 AUXILIARY OUTPUT #2, EVENT & TIME
Segment 1: Event number for output # 2
1=Fire alarm
Segment 2: Timing for output # 2
10 seconds
49 - 50
RESERVED
L
51 20 AUTOTEST
CONTROL
Seg 1: Program a "1" if the interval is hours, a
"0" if in days. Add a
A
2" to suppress the daily
test or a
A
3" to suppress the hourly test.
1
Seg 2: Program the autotest interval from 1-
255 days or hours.
24
Seg 3: Program the autotest report in 24-hour
time format.
2
Seg 4: Program the autotest report time,
minutes after the hour.
0
52 21 OPENING
TIME
Seg 1: Hour of the opening time.
8
Seg 2: Minutes after the hour of opening time.
0
53
21
CLOSING TIME / AUTO ARMING TIME
Seg 1: Hour of closing time / auto arming time.
20
Seg 2: Minutes after hour of closing / auto
arming time.
0
54
21
DAYS OF THE WEEK SYSTEM IS OPEN
Segment
1:
Sunday Monday Tuesday
Wednesday
Thursday Friday Saturday Reserved
1 2 3 4 5 6 7 8
55
21
DAYS OF THE WEEK "AUTO ARMING" WILL OCCUR
Segment
1:
Sunday Monday Tuesday
Wednesday
Thursday Friday Saturday
Disable retry
timer
1 2 3 4 5 6 7 8
WWW.DIYALARMFORUM.COM