NX-4V2 Control
29
LOC
PG
DESCRIPTION
DEFAULT
PROGRAM DATA
L
19
14 DOWNLOAD ACCESS CODE
8-4-8-0-0-0-0-0
_ _ _ _ _ _ _ _
L
20
14 RINGS TO ANSWER DOWNLOAD
8
_
L
21 15 DOWNLOAD
CONTROL
Segment
1
(Circle Numbers To Program)
1 = Enables two call answering machine defeat
2 = Enables tone sniff answering machine defeat
3 = Requires callback before downloading
4 = Shutdown control panel
5 = Lock out local programming
6 = Lock out communicator programming
7 = Lock out download section
8 = Enables callback at autotest interval
L
22
15
CALLBACK PHONE NUMBER
14-14-14-14-14-14-14-14-14-14-
14-14-14-14-14-14-14-14-14-14
__ __ __ __ __ __ __ __ __ __
__ __ __ __ __ __ __ __ __ __
L
23 15 FEATURE
SELECTION
Segment
1
(Circle Numbers To Program)
1 = Quick Arm
2 = Re-Exit
3 =
Auto Bypass
4 = Silent Panic
5 =
Audible Panic
6 = Auxiliary 1
7 = Auxiliary 2
8 = Multi Keypress Tamper
Segment
2
(Circle Numbers To Program)
1 = LED extinguish enable
2 = Require user code for bypassing zones
3 = Bypass sounder alert
4 =
AC power/low battery sounder alert
5 = Enables bypass toggle
6 = Enables silent auto arm
7 = Enables automatic instant
8 = Enables Instant mode toggle
Segment 3
(Circle Numbers To Program)
1
=
Open/Close
2 = Bypass
3 = Restore
4 = Trouble
5 = Tamper
6 =
Cancel
7 =
Recent Closing
8 =
Exit Error
Segment
4
(Circle Numbers To Program)
1 = Late to Close / Early to Open
2 = Auto Arm in Stay Mode
3 = Disables door delays in Night mode
4-8 = Reserved
Segment 5 RESERVED
L
24
16 ENTRY / EXIT TIMERS
Segment
1
(Entry Time 1)
30
Segment 2 (Exit Time 1)
60
Segment
3
(Entry Time 2)
30
Segment
4
(Exit Time 2)
60
Segments 5 & 6
Reserved
L
25
17
ZONES 1-8, ZONE TYPES
3-5-6-6-6-6-6-6
_ _ _ _ _ _ _ _
29-36 17
RESERVED
L
37
17
SIREN AND SYSTEM SUPERVISION
Segment 1 (Circle Numbers To Program)
1
=
Siren sounds for telephone line cut while armed.
2 =
Siren sounds for telephone line cut while disarmed.
3 = Siren blast at arming.
4 = Siren blast at exit delay expiration.
5 = Siren blast at closing kissoff.
6 = Siren sounds during a cross-zone verification time.
7 =
Siren sounds for a tamper.
8 = Siren blast one time for keyswitch arming, two times for disarming.
(
Note
: Must be disabled for SIA CP-01
installations.)
Segment 2 (Circle Numbers To Program)
1 = Convert siren driver to voltage out.
2 = Siren sounds for expander trouble (required for U.L.).
3 = Immediate Restore by zone.
4 = Dynamic battery test performed upon arming.
5 = Battery missing test performed every 12 seconds.
6 =
Manual bell test performed during [
r
]-[4]-[4] test function.
7 = Manual communicator test performed during [
r
]-[
4
]-[
4
] test function.
8 = Box tamper enabled.
WWW.DIYALARMFORUM.COM