NX-4V2 Control
17
DATA
DESCRIPTION OF DEFAULT ZONE TYPES
20
ENTRY/EXIT DELAY 2 WITH TAMPER ENABLED-
A trip will start entry delay 2. The lack of a trip during exit delay will
enable the Automatic Bypass or Instant mode if so programmed.
This zone type can be used to enable tamper on a
wireless transmitter.
21
GAS DETECTION-
Creates an instant alarm regardless of the armed state of the control panel. It will display on the
keypad and activate the keypad sounder.
22
LOW TEMP DETECTION-
Creates an instant silent alarm regardless of the armed state of the control panel. It will display
on the keypad and activate the keypad sounder.
23
HIGH TEMP DETECTION-
Creates an instant silent alarm regardless of the armed state of the control panel. It will
display on the keypad and activate the keypad sounder.
24
MANUAL FIRE -
This zone will illuminate the Fire LED and sound the temporal siren each time the zone is shorted. It will
also rapidly flash the Fire LED indicating a trouble if the zone is open.
25
CHIME ONLY -
Creates no alarm regardless of the armed state of the control panel. It will chime anytime it is faulted and
will display on the keypad. Local only.
26
INTERIOR FOLLOWER DELAY 2 -
This zone will be instant when the system is armed and no entry or exit delay is
being timed. It is delayed during entry and exit delay 2 times. This zone will automatically bypass if enabled in Segment 1
of Location 23.
27
INTERIOR FOLLOWER FORCE ARMABLE -
This zone will be instant when the system is armed and no entry or exit
delay is being timed. It is delayed during entry and exit delay 1 times. This zone will automatically bypass if enabled in
Segment 1 of Location 23.
28
ENTRY/EXIT FORCE ARMABLE DELAY 2 -
A trip will start entry delay 2. The lack of a trip during exit delay will enable
the Automatic Bypass or Instant mode if so programmed.
29
INTERIOR FOLLOWER WITH ACTIVITY SUPERVISION ENABLED -
This zone will be instant when the system is
armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. It will send a report if the
zone activity time is reached without a change of state. Refer to Location 40 / Segment 11. This zone will automatically
bypass if enabled in Segment 1 of Location 23.
30
ENTRY/EXIT WITH ACTIVITY SUPERVISION ENABLED-
A trip will start entry delay 1. It will send a report if the zone
activity time is reached without a change of state. Refer to Location 40 / Segment 11. The lack of a trip during exit delay
will enable the Automatic Bypass or Instant mode if so programmed.
L
25
ZONES 1-8 ZONE TYPE 8............. numerical
Location 25 contains the Zone Type for zones 1-8. Segment 1 is for zone 1, and Segment 8 is for zone 8. Default Zone Types are
found in the table on page 16. To customize a Zone Type, see page 23.
26 - 36
RESERVED
L
37
SIREN AND SYSTEM SUPERVISION 7............. feature
select
Location 37 is used to enable various system feature and reporting options. (For specific definitions, refer to the Glossary beginning on
page 35)
Segment 1:
1 = On if siren sounds for "Telephone Line Cut" when armed.
2 = On if siren sounds for "Telephone Line Cut" when disarmed.
3 = On if siren blast at arming.
4 = On if siren blast at exit expiration.
5 = On if siren blast at closing kissoff.
6 = On if siren sounds during a "Cross Zone" verification time.
7 = On if siren sounds for a Zone or Box Tamper.
8 = On if siren blasts 1 time for keyswitch or wireless arming; 2 times for disarming.
(
Note
: Must be disabled for SIA CP-01 installations.)
Segment 2:
1 = On if siren driver should be a voltage output. Off if on board siren driver enabled.
2 = On if siren sounds for expander trouble (required for UL installations).
3 = On for Immediate Restore by zone. Off for zones to restore only when siren is off.
4 = On if Dynamic Battery Test performed at arming. Off if performed at disarming. (See location 40)
5 = On if Battery Missing Test is performed every 12 seconds.
6 = On if Manual Bell Test performed during [
r
]-[
4
]-[
4
] test function.
7 = On if Manual Communicator Test performed during [
r
]-[
4
]-[
4
] test function.
8 = On if Box Tamper terminals on the control panel are enabled.
WWW.DIYALARMFORUM.COM