24
NX-4V2 Control
5 = On if Zone Type can be bypassed.
6 = On if Zone Type is included in the group shunt.
7 = On if Zone Type is force armable.
8 = On if Zone Type is entry guard.
Segment 3:
1- On enables Fast Loop Response. (50mS)- Off= 500mS
2- On enables Double End Of Line Tamper zone. (Mainly used for tamper on wireless zones)
3- On enables Trouble Reporting zone. (Day zone and Fire zones)
4- On if Zone Type is a Cross Zone.
5- On enables Dialer Delay zone. (See location 40, page 19)
6- On if Zone Type will swinger shutdown. (See location 38, page 18)
7- On enables Restore reporting.
8- On enables Listen-In. (See location 40, page 19)
Segment 4:
1 = On enables Zone Activity Monitor. (See location 40, page 19)
2 = On enables End of Line Resistor Defeat on Non-Fire/Non-Keyswitch zones.
3 = On enables zone to act as
request to exit
input / disables for alarm activation.
4 = On enables zone to act as access entry point (Refer to NX-1700E card reader instruction manual. Do not enable this segment
unless configured with Access Control.)
5-8 = Reserved.
Segment 5:
Reserved.
112
ZONE TYPE 2 ALARM EVENT CODE
1 ............ numerical
Location 112 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the list on
page 39. The zone ID will be that zone that is in alarm. If 4+2 format is being used, refer to Location 110 on page 23 for details.
113
ZONE TYPE 2 CHARACTERISTIC SELECT
5 ............ feature select
Use "Zone Type Characteristic Selections" described in Location 111, page 23
114
ZONE TYPE 3 ALARM EVENT CODE
1 ............ numerical
Location 114 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the list on
page 39. The zone ID will be that zone that is in alarm. If 4+2 format is being used, refer to Location 110 on page 23 for details.
115
ZONE TYPE 3 CHARACTERISTIC SELECT
5 ............ feature select
Use "Zone Type Characteristic Selections" described in Location 111, page 23
116
ZONE TYPE 4 ALARM EVENT CODE
1 ............ numerical
Location 116 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the list on
page 39. The zone ID will be that zone that is in alarm. If 4+2 format is being used, refer to Location 110 on page 23 for details.
117
ZONE TYPE 4 CHARACTERISTIC SELECT
5 ............ feature select
Use "Zone Type Characteristic Selections" described in Location 111, page 23
118
ZONE TYPE 5 ALARM EVENT CODE
1 ............ numerical
Location 118 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the list on
page 39. The zone ID will be that zone that is in alarm. If 4+2 format is being used, refer to Location 110 on page 23 for details.
119
ZONE TYPE 5 CHARACTERISTIC SELECT
5 ............ feature select
Use "Zone Type Characteristic Selections" described in Location 111, page 23
120
ZONE TYPE 6 ALARM EVENT CODE
1 ............ numerical
Location 120 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the list on
page 39. The zone ID will be that zone that is in alarm. If 4+2 format is being used, refer to Location 110 on page 23 for details.
121
ZONE TYPE 6 CHARACTERISTIC SELECT
5 ............ feature select
Use "Zone Type Characteristic Selections" described in Location 111, page 23
122
ZONE TYPE 7 ALARM EVENT CODE
1 ............ numerical
Location 122 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen from the list on
page 39. The zone ID will be that zone that is in alarm. If 4+2 format is being used, refer to Location 110 on page 23 for details.
123
ZONE TYPE 7 CHARACTERISTIC SELECT
5 ............ feature select
Use "Zone Type Characteristic Selections" described in Location 111, page 23
WWW.DIYALARMFORUM.COM