
16
NX-4V2 Control
L
24
ENTRY / EXIT TIMERS
6 ............ numerical
Location 24 is used to program the Entry/Exit times. There are 2 separate Entry/Exit times.
Segment 1,
Entry time 1:
This is the entry time that will be used when a delay 1 zone type initiates an entry delay. Valid
entries are 30-255 seconds.
Segment 2,
Exit time 1:
This is the exit time that will be used for all zones designated as delay 1. Valid entries are 45-255
seconds.
Segment 3,
Entry
time
2
:
This is the entry time that will be used when a delay 2 zone type initiates an entry delay. Valid
entries are 30-255 seconds.
Segment 4,
Exit time 2:
This is the exit time that will be used for all zones designated as delay 2. Valid entries are 45-255
seconds.
Segments 5 & 6
Reserved.
XIII. DEFAULT
ZONE
TYPES (Configurations)
Zones can be programmed to be one of thirty different zone types (configurations). Zone types 17 - 20 can be used for wireless or
hardwired zones using European double EOL configuration. The default zone types are listed below. These zone types can be
customized by programming locations 110-169.
DATA
DESCRIPTION OF DEFAULT ZONE TYPES
1
DAY ZONE -
Instant when system is armed trouble zone when system is disarmed.
2
24-HOUR AUDIBLE
- Creates an instant yelping siren alarm regardless of the armed state of the control panel.
3
ENTRY/EXIT DELAY 1-
A trip will start entry delay 1. The lack of a trip during exit delay will enable the Automatic
Bypass or Instant mode if so programmed.
4
FOLLOWER WITH AUTO- BYPASS DISABLED -
This zone will be instant when the system is armed and no entry or
exit delays are being timed. It is delayed during entry and exit delay 1 times. This zone will not automatically bypass even
if enabled in Segment 1 of Location 23.
5
INTERIOR FOLLOWER WITH AUTO- BYPASS ENABLED -
This zone will be instant when the system is armed and no
entry or exit delay is being timed. It is delayed during entry and exit delay 1 times. This zone will automatically bypass if
enabled in Segment 1 of Location 23.
6
INSTANT -
This zone creates an instant alarm whenever it is tripped and the Armed LED is on.
7
24-HOUR SILENT -
Creates an instant silent alarm regardless of the armed state of the control panel. It will not display
on the keypad.
8
FIRE -
This zone will light the Fire LED and sound the temporal siren each time the zone is shorted. It will also rapidly
flash the Fire LED indicating a trouble if the zone is open.
9
ENTRY/EXIT DELAY 2-
A trip will start entry delay 2. The lack of a trip during exit delay will enable the Automatic
Bypass or Instant mode if so programmed.
10
24-HOUR SILENT SUPERVISED-
Creates an instant silent alarm regardless of the armed state of the control panel. It
will display on the keypad.
11
RESERVED
12
INTERIOR FOLLOWER WITH "CROSS ZONE" ENABLED
- This zone will be instant when the system is armed and no
entry or exit delay is being timed. It is delayed during entry and exit delay times. If a "Cross Zone" is not being timed it will
start a "Cross Zone" timer. If a "Cross Zone" is being timed it will create an instant alarm. This zone will automatically
bypass when enabled in Segment 1 of Location 23.
13
INSTANT ENTRY GUARD -
This zone creates an instant alarm whenever it is tripped and the Stay LED is off. It will start
an entry delay time 2 if it is tripped and the system is armed and the Stay LED is on.
14
ENTRY/EXIT DELAY 1 WITH GROUP BYPASS ENABLED -
A trip will start entry delay 1. This zone will bypass when
the "Group Bypass" command is entered at the keypad. The lack of a trip during exit delay will enable the Automatic
Bypass or Instant mode if so programmed.
15
INTERIOR FOLLOWER WITH GROUP BYPASS ENABLED -
This zone will be instant when the system is armed and no
entry or exit delays are being timed. It is delayed during entry/exit delay times. This zone will bypass when the "Group
Bypass" command is entered at the keypad. This zone will automatically bypass if enabled in Segment 1 of Location 23.
16
INSTANT WITH GROUP BYPASS ENABLED -
This zone creates an instant alarm whenever it is tripped and the Armed
LED is on. This zone will bypass when the "Group Bypass" command is entered at the keypad.
17
ENTRY/EXIT DELAY 1 WITH TAMPER ENABLED-
A trip will start entry delay 1. The lack of a trip during exit delay will
enable the Automatic Bypass or Instant mode if so programmed.
This zone type can be used to enable tamper on a
wireless transmitter.
18
INTERIOR FOLLOWER WITH TAMPER AND AUTO-BYPASS ENABLED -
This zone will be instant when the system is
armed and no entry or exit delay is being timed. It is delayed during entry and exit delay times. This zone will
automatically bypass if enabled in Segment 1 of Location 23.
This zone type can be used to enable tamper on a wireless
transmitter.
19
INSTANT WITH TAMPER ENABLED
- This zone creates an instant alarm whenever it is tripped and the Armed LED is
on.
This zone type can be used to enable tamper on a wireless transmitter
.
WWW.DIYALARMFORUM.COM