GE Multilin
M60 Motor Protection System
H-3
APPENDIX H
H.1 CHANGE NOTES
H
1-1
1-1
Update
Updated Figure 1-1 Rear Nameplate
3-8
3-8
Update
Updated Figure 3-10 Rear Terminal View
Table H–6: MAJOR UPDATES FOR M60 MANUAL REVISION Y1 (Sheet 1 of 2)
PAGE
(X2)
PAGE
(Y1)
CHANGE
DESCRIPTION
All
All
Delete
Deleted content pertaining to Ethernet switch
Title
Title
Update
Changed part numbers. Updated address and contact information.
1-1
1-1
Update
Updated address and contact information
2-
2-
Add
Added CPU options T, U, and V to order code table
2-
2-
Delete
Removed E, G, H, J, S from CPU options from order code tables
2-8
2-8
Delete
Deleted 9S, 2S, 2T from replacement module order code Tables 2-7 and 2-8
2-18
2-18
Update
Updated Ethernet fiber table in section 2.2.8 Communications
3-10
3-10
Update
Updated Figure 3-12 Typical Wiring Diagram
3-23
3-23
Update
Deleted references to COM 1 RS485 port in section 3.2.9 CPU Communication Ports. Revised
text and Figure 3-24 CPU Module Communications Wiring to include only modules T, U, V in
section 3.2.9a.
5-1
5-1
Update
Updated the front panel main menu to include the CyberSentry security menu
5-15
5-15
Update
Update Communications main menu to remove the SNTP Protocol submenu
5-16
5-16
Delete
Deleted references to COM 1 RS485 port in section 5.2.4b Serial Ports
5-16
5-16
Add
Added section 5.2.4c Ethernet Network Topology
5-17
5-17
Update
Updated Networks section 5.2.4d to include all three Ethernet ports
5-17
5-17
Update
Added 0 as valid number to section 5.2.4e Modbus Protocol section
5-40
5-
Delete
Deleted Local Time Offset, Daylight Savings Time, DST (start/stop for month/day/hour) from Real
Time Clock menu
5-
5-40
Add
Added submenus Precision Time Protocol, SNTP Protocol, and Local Time and Synchronizing
Source settings to Real Time Clock menu
5-
5-41
Add
Added new Precision Time Protocol (1588) menu and setting descriptions
5-
5-
Update
Changed Communication to Real Time Clock in SNTP protocol settings path. Moved SNTP
Protocol menu and settings descriptions to Real Time Clock subsection
5-37
5-
Deleted
Deleted section k) SNTP Protocol and the settings descriptions
5-
5-44
Add
Added new section for Local Time menu settings and settings description
5-
5-52
Add
Added new PTP Fail menu item to the User-Programmable Self Tests menu
5-
5-
Add
Added PTP Failure and CLOCK UNSYNCHRONIZED to Flexlogic Operands table
5-
5-114
Update
Added row for DeltaTime to Table 5-: FlexElement Base Units
5-231
5-231
Delete
Deleted section 5.8.5c Remote Devices: ID of Device for Receiving GSSE/GOOSE Messages,
meaning the Settings > Input/Outputs > Remote Devices settings
5-
5-254
Add
Added new CyberSentry security section and main menu, local passwords, session settings,
restore defaults, and supervisory subsections to Chapter 5
6-1
6-1
Update
Update Actual Values main menu to include Real Time Clock Synchronization submenu
6-
6-7
Add
Added new section for Real Time Clock synchronizing consisting of the menu of settings and the
setting descriptions
6-11
6-11
Delete
Deleted section 6.2.20 Ethernet Switch
6-
6-13
Add
Added new section 6.2.21 Remaining Connection Status
7-
7-1
Add
Added Security command to the Commands main menu
7-
7-3
Add
Added Reboot Relay command and description to the Relay Maintenance menu items
7-
7-
Add
Added Security menu and submenu commands and descriptions to the Command menu
Table H–5: MAJOR UPDATES FOR M60 MANUAL REVISION Y2 (Sheet 2 of 2)
PAGE
(Y1)
PAGE
(Y2)
CHANGE
DESCRIPTION
Содержание M60 UR Series
Страница 10: ...x M60 Motor Protection System GE Multilin TABLE OF CONTENTS ...
Страница 98: ...3 40 M60 Motor Protection System GE Multilin 3 3 DIRECT INPUT OUTPUT COMMUNICATIONS 3 HARDWARE 3 ...
Страница 128: ...4 30 M60 Motor Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 238: ...5 110 M60 Motor Protection System GE Multilin 5 4 SYSTEM SETUP 5 SETTINGS 5 Figure 5 29 DISCONNECT SWITCH SCHEME LOGIC ...
Страница 410: ...5 282 M60 Motor Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 413: ...GE Multilin M60 Motor Protection System 6 3 6 ACTUAL VALUES 6 1 OVERVIEW 6 FIRMWARE REVISIONS See page 6 29 ...
Страница 440: ...6 30 M60 Motor Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 452: ...7 12 M60 Motor Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Страница 462: ...9 8 M60 Motor Protection System GE Multilin 9 2 BATTERIES 9 MAINTENANCE 9 ...
Страница 474: ...A 12 M60 Motor Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 584: ...B 110 M60 Motor Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 614: ...C 30 M60 Motor Protection System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 630: ...E 10 M60 Motor Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Страница 642: ...F 12 M60 Motor Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 644: ...G 2 M60 Motor Protection System GE Multilin G 1 RADIUS SERVER CONFIGURATION APPENDIX G G ...
Страница 652: ...H 8 M60 Motor Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Страница 662: ...x M60 Motor Protection System GE Multilin INDEX ...