B-90
M60 Motor Protection System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
F552
ENUMERATION: RTD INPUT OPEN
F600
UR_UINT16: FLEXANALOG PARAMETER
Corresponds to the Modbus address of the value used when this
parameter is selected. Only certain values may be used as Flex-
Analogs (basically all metering quantities used in protection).
F601
ENUMERATION: COM2 PORT USAGE
F602
ENUMERATION: RRTD BAUD RATE
F603
ENUMERATION: RRTD TRIP VOTING
F605
ENUMERATION: REMOTE DOUBLE-POINT STATUS INPUT
STATUS
F606
ENUMERATION: REMOTE DOUBLE-POINT STATUS INPUT
F611
ENUMERATION: GOOSE RETRANSMISSION SCHEME
F612
UR_UINT16: FLEXINTEGER PARAMETER
This 16-bit value corresponds to the Modbus address of the
selected FlexInteger parameter. Only certain values may be used
as FlexIntegers.
F615
ENUMERATION: IEC 61850 REPORT DATASET ITEMS
11
RTD Input 10
12
RTD Input 11
13
RTD Input 12
Enumeration
RTD open
0
None
1
Alarm
2
Block
Enumeration
COM2 port usage
0
RS485
1
RRTD
2
GPM-F
3
RRTD and GPM-F
Enumeration
RRTD baud rate
0
1200 bps
1
2400 bps
2
4800 bps
3
9600 bps
4
19200 bps
Enumeration
RRTD trip voting
0
None
1
Group
2
Remote RTD 1
3
Remote RTD 2
4
Remote RTD 3
5
Remote RTD 4
6
Remote RTD 5
7
Remote RTD 6
8
Remote RTD 7
9
Remote RTD 8
10
Remote RTD 9
11
Remote RTD 10
Enumeration
RTD trip voting
12
Remote RTD 11
13
Remote RTD 12
Enumeration
Remote DPS input status
0
Intermediate
1
Off
2
On
3
Bad
Enumeration
Remote double-point status input
0
None
1
Remote input 1
2
Remote input 2
3
Remote input 3
64
Remote input 64
Enumeration
Configurable GOOSE retransmission scheme
0
Heartbeat
1
Aggressive
2
Medium
3
Relaxed
Enumeration
IEC 61850 report dataset items
0
None
1
PDIF1.ST.Str.general
2
PDIF1.ST.Op.general
3
PDIF2.ST.Str.general
4
PDIF2.ST.Op.general
5
PDIF3.ST.Str.general
6
PDIF3.ST.Op.general
7
PDIF4.ST.Str.general
8
PDIF4.ST.Op.general
9
PDIS1.ST.Str.general
Enumeration
RRTD trip voting
Содержание M60 UR Series
Страница 10: ...x M60 Motor Protection System GE Multilin TABLE OF CONTENTS ...
Страница 98: ...3 40 M60 Motor Protection System GE Multilin 3 3 DIRECT INPUT OUTPUT COMMUNICATIONS 3 HARDWARE 3 ...
Страница 128: ...4 30 M60 Motor Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 238: ...5 110 M60 Motor Protection System GE Multilin 5 4 SYSTEM SETUP 5 SETTINGS 5 Figure 5 29 DISCONNECT SWITCH SCHEME LOGIC ...
Страница 410: ...5 282 M60 Motor Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 413: ...GE Multilin M60 Motor Protection System 6 3 6 ACTUAL VALUES 6 1 OVERVIEW 6 FIRMWARE REVISIONS See page 6 29 ...
Страница 440: ...6 30 M60 Motor Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 452: ...7 12 M60 Motor Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Страница 462: ...9 8 M60 Motor Protection System GE Multilin 9 2 BATTERIES 9 MAINTENANCE 9 ...
Страница 474: ...A 12 M60 Motor Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 584: ...B 110 M60 Motor Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 614: ...C 30 M60 Motor Protection System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 630: ...E 10 M60 Motor Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Страница 642: ...F 12 M60 Motor Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 644: ...G 2 M60 Motor Protection System GE Multilin G 1 RADIUS SERVER CONFIGURATION APPENDIX G G ...
Страница 652: ...H 8 M60 Motor Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Страница 662: ...x M60 Motor Protection System GE Multilin INDEX ...