GE Multilin
M60 Motor Protection System
B-31
APPENDIX B
B.4 MEMORY MAPPING
B
4494
...Repeated for CT Bank 6
VT Settings (Read/Write Setting) (6 Modules)
4500
Phase VT 1 Connection
0 to 1
---
1
F100
0 (Wye)
4501
Phase VT 1 Secondary
25 to 240
V
0.1
F001
664
4502
Phase VT 1 Ratio
1 to 24000
:1
1
F060
1
4504
Auxiliary VT 1 Connection
0 to 6
---
1
F166
1 (Vag)
4505
Auxiliary VT 1 Secondary
25 to 240
V
0.1
F001
664
4506
Auxiliary VT 1 Ratio
1 to 24000
:1
1
F060
1
4508
...Repeated for VT Bank 2
4510
...Repeated for VT Bank 3
4518
...Repeated for VT Bank 4
4520
...Repeated for VT Bank 5
4528
...Repeated for VT Bank 6
Source Settings (Read/Write Setting) (6 Modules)
4580
Source 1 Name
0 to 1
---
---
F206
“SRC 1"
4583
Source 1 Phase CT
0 to 63
---
1
F400
0
4584
Source 1 Ground CT
0 to 63
---
1
F400
0
4585
Source 1 Phase VT
0 to 63
---
1
F400
0
4586
Source 1 Auxiliary VT
0 to 63
---
1
F400
0
4587
...Repeated for Source 2
458E
...Repeated for Source 3
4595
...Repeated for Source 4
459C
...Repeated for Source 5
45A3
...Repeated for Source 6
Power System (Read/Write Setting)
4600
Nominal Frequency
25 to 60
Hz
1
F001
60
4601
Phase Rotation
0 to 1
---
1
F106
0 (ABC)
4602
Frequency And Phase Reference
0 to 5
---
1
F167
0 (SRC 1)
4603
Frequency Tracking Function
0 to 1
---
1
F102
1 (Enabled)
Breaker Control (Read/Write Settings) (4 Modules)
47D0
Breaker 1 Function
0 to 1
---
1
F102
0 (Disabled)
47D1
Breaker 1 Name
---
---
---
F206
“Bkr 1"
47D4
Breaker 1 Mode
0 to 1
---
1
F157
0 (3-Pole)
47D5
Breaker 1 Open
0 to 4294967295
---
1
F300
0
47D7
Breaker 1 Close
0 to 4294967295
---
1
F300
0
47D9
Breaker 1 Phase A / Three-pole Closed
0 to 4294967295
---
1
F300
0
47DB
Breaker 1 Phase B Closed
0 to 4294967295
---
1
F300
0
47DD
Breaker 1 Phase C Closed
0 to 4294967295
---
1
F300
0
47DF
Breaker 1 External Alarm
0 to 4294967295
---
1
F300
0
47E1
Breaker 1 Alarm Delay
0 to 65.535
s
0.001
F003
0
47E3
Breaker 1 Pushbutton Control
0 to 1
---
1
F102
0 (Disabled)
47E4
Breaker 1 Manual Close Recall Time
0 to 4294967295
s
0.001
F003
0
47E6
Breaker 1 Out of Service
0 to 4294967295
---
1
F300
0
47E8
Breaker 1 Block Open
0 to 4294967295
---
1
F300
0
47EA
Breaker 1 Block Close
0 to 4294967295
---
1
F300
0
47EC
Breaker 1 Phase A / Three-pole Opened
0 to 4294967295
---
1
F300
0
47EE
Breaker 1 Phase B Opened
0 to 4294967295
---
1
F300
0
47F0
Breaker 1 Phase C Opened
0 to 4294967295
---
1
F300
0
47F2
Breaker 1 Operate Time
0 to 65.535
s
0.001
F001
70
47F3
Breaker 1 Events
0 to 1
---
1
F102
0 (Disabled)
47F4
Reserved
0 to 65535
s
1
F001
0
47F5
...Repeated for breaker 2
481A
...Repeated for breaker 3
483F
...Repeated for breaker 4
Table B–9: MODBUS MEMORY MAP (Sheet 24 of 66)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Содержание M60 UR Series
Страница 10: ...x M60 Motor Protection System GE Multilin TABLE OF CONTENTS ...
Страница 98: ...3 40 M60 Motor Protection System GE Multilin 3 3 DIRECT INPUT OUTPUT COMMUNICATIONS 3 HARDWARE 3 ...
Страница 128: ...4 30 M60 Motor Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Страница 238: ...5 110 M60 Motor Protection System GE Multilin 5 4 SYSTEM SETUP 5 SETTINGS 5 Figure 5 29 DISCONNECT SWITCH SCHEME LOGIC ...
Страница 410: ...5 282 M60 Motor Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Страница 413: ...GE Multilin M60 Motor Protection System 6 3 6 ACTUAL VALUES 6 1 OVERVIEW 6 FIRMWARE REVISIONS See page 6 29 ...
Страница 440: ...6 30 M60 Motor Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Страница 452: ...7 12 M60 Motor Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Страница 462: ...9 8 M60 Motor Protection System GE Multilin 9 2 BATTERIES 9 MAINTENANCE 9 ...
Страница 474: ...A 12 M60 Motor Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Страница 584: ...B 110 M60 Motor Protection System GE Multilin B 4 MEMORY MAPPING APPENDIX B B ...
Страница 614: ...C 30 M60 Motor Protection System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Страница 630: ...E 10 M60 Motor Protection System GE Multilin E 1 IEC 60870 5 104 PROTOCOL APPENDIX E E ...
Страница 642: ...F 12 M60 Motor Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Страница 644: ...G 2 M60 Motor Protection System GE Multilin G 1 RADIUS SERVER CONFIGURATION APPENDIX G G ...
Страница 652: ...H 8 M60 Motor Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Страница 662: ...x M60 Motor Protection System GE Multilin INDEX ...