250
1.
Fill a syringe with room air. Pass at least 20 cc of air through each thin
silicone tube to ensure removal of any residual content.
2.
Connect the one-way valve to the long corrugated tube.
3.
Connect the Flow Transducer and the Y-Connector.
4.
Connect the one-way valve to the Y-Connector.
5.
Connect the thin silicone tubes to the tube holders on the corrugated
tube so that they run parallel to the corrugated tube
WARNING
Ensure that the One-Way Valve is installed in its proper direction
CAUTION
Verify that the membrane edge is installed properly. The membrane’s edge should
not overlap the exhalation cap edge.
NOTE
The exhalation cap contains a tube connector for exhalation control. Observe
that the membrane is inserted in the proper orientation. Assemble the upper
and lower parts exhalation valve together.
6.
Check that the groove in the cap mates with the pin in the valve housing
in the same orientation.
7.
Check that all tube holders on corrugated tube are firmly supported. See
that all other connections are stable and that there are no loose ends.
8.
Check that all tube holders on corrugated tube are firmly supported. See
that all other connections are stable and that there are no loose ends.
9.
Follow the Instructions for use given above for connecting the patient
circuit to ventilator.
10.
Perform the standard Operational Verification (O.V.T) test procedure, as
described on page 60. It is recommended that the patient circuit
connection be periodically checked for proper integrity and
performance.
DUAL LIMB PATIENT CIRCUIT ADAPTER
KIT CONTENTS
The Dual limb kit (GE PN M1169907) includes:
Item no.
Item
Part number
1 Exhalation
Valve
Adapter
2
Captive Screw (x2)
3 Exhalation
Valve
Holder
4
Exhalation Valve, Low Resistance
Содержание iVent 201 Series
Страница 1: ...GE Healthcare iVentTM201 User s Reference Manual Revision 13...
Страница 2: ...VersaMed a General Electric Company doing business as GE Healthcare...
Страница 4: ......
Страница 14: ......
Страница 42: ......
Страница 68: ...56 Notes...
Страница 70: ......
Страница 98: ...86 Notes...
Страница 100: ......
Страница 140: ...128 Notes...
Страница 142: ......
Страница 152: ......
Страница 154: ......
Страница 184: ......
Страница 201: ...7 Care Maintenance and Tests 189 Notes...
Страница 202: ......
Страница 203: ...Appendix A Glossary 191 APPENDIX A GLOSSARY...
Страница 204: ......
Страница 210: ...198 Notes...
Страница 211: ...Appendix B Warranty 199 APPENDIX B WARRANTY...
Страница 212: ......
Страница 215: ...Appendix C Operating Theory 203 APPENDIX C OPERATING THEORY...
Страница 216: ......
Страница 219: ...Appendix C Operating Theory 207...
Страница 220: ......
Страница 221: ...Appendix C Operating Theory 209 Notes...
Страница 222: ......
Страница 223: ...Appendix D Theory of Breath Delivery 211 APPENDIX D THEORY OF BREATH DELIVERY...
Страница 224: ......
Страница 233: ...Appendix D Theory of Breath Delivery 221 Notes...
Страница 234: ......
Страница 235: ...Appendix E Ventilation Modes 223 APPENDIX E VENTILATION MODES...
Страница 236: ......
Страница 243: ...Appendix E Ventilation Modes 231 Notes...
Страница 244: ......
Страница 246: ......
Страница 252: ...240 Notes...
Страница 253: ...Appendix G Accessories 241 APPENDIX G ACCESSORIES...
Страница 254: ......
Страница 276: ...264 5 Fasten the external battery using the strap belt Figure 199 Connecting the Optional Battery Bag...
Страница 277: ...Appendix H Remote Alarm Connector 265 APPENDIX H REMOTE ALARM CONNECTOR...
Страница 278: ......
Страница 280: ......
Страница 281: ...Appendix I Part Numbers and Accessories 269 APPENDIX I PART NUMBERS AND ACCESSORIES...
Страница 282: ......
Страница 286: ...274...
Страница 289: ...Index 277...