The amber charge LED lights to indicate that the iVent
TM
201 is connected to
external power.
The green on LED indicates that the power is switched on.
The Screen
The LCD screen is organized to allow rapid access to the ventilator’s functions.
The monitoring or control of any critical parameter is performed with ease.
Baseline indicators and alarms – emergency alerts and alert status
indicators, power and battery states, date and time, and the Menu access
button -- are all displayed along the bottom of the screen indicators.
Set values are displayed in black
Measured and calculated values are displayed in blue -- flashing values
indicate that a set value was not obtained.
Here is a quick overview of the most important screens:
The
Main Screen
(Figure 26) is the first screen displayed when the iVent
TM
201 is
placed in
Standby
or
Start
Mode.
The slider gauge along the left side of the screen displays the real-time measured
Peak Inspiratory Pressure below a digital readout of the last peak inspiratory
pressure value.
On the top left of the screen, a large shows the total measured respiratory rate in
breaths per minute in large blue numbers. The selected/default respiratory rate
is shown in smaller black numbers below. Proceed to the
Respiratory Rate
option to enable and change the number of breaths per minute.
Beside the
Respiratory Rate
option, there is also the
Tidal Volume
option. This
displays the exhaled Tidal Volume and allows adjustment to the set Tidal Volume.
(See page 69 for more details about the Tidal Volume display
.)
On the top right of the screen is the
Mode Selection
option, which shows the
current ventilation mode. This option allows you to change modes (See page 62).
Selecting and clicking on a mode brings up the appropriate Mode screen for the
selected ventilation mode. Use this screen to view or adjust ventilation
parameters.
When the ventilator is operating, the middle section of the Main screen displays
pressure/flow waveforms. The optional waveforms package permits a host of
possible display characteristics. (See page 108 for a guide to the waveform
package.)
Содержание iVent 201 Series
Страница 1: ...GE Healthcare iVentTM201 User s Reference Manual Revision 13...
Страница 2: ...VersaMed a General Electric Company doing business as GE Healthcare...
Страница 4: ......
Страница 14: ......
Страница 42: ......
Страница 68: ...56 Notes...
Страница 70: ......
Страница 98: ...86 Notes...
Страница 100: ......
Страница 140: ...128 Notes...
Страница 142: ......
Страница 152: ......
Страница 154: ......
Страница 184: ......
Страница 201: ...7 Care Maintenance and Tests 189 Notes...
Страница 202: ......
Страница 203: ...Appendix A Glossary 191 APPENDIX A GLOSSARY...
Страница 204: ......
Страница 210: ...198 Notes...
Страница 211: ...Appendix B Warranty 199 APPENDIX B WARRANTY...
Страница 212: ......
Страница 215: ...Appendix C Operating Theory 203 APPENDIX C OPERATING THEORY...
Страница 216: ......
Страница 219: ...Appendix C Operating Theory 207...
Страница 220: ......
Страница 221: ...Appendix C Operating Theory 209 Notes...
Страница 222: ......
Страница 223: ...Appendix D Theory of Breath Delivery 211 APPENDIX D THEORY OF BREATH DELIVERY...
Страница 224: ......
Страница 233: ...Appendix D Theory of Breath Delivery 221 Notes...
Страница 234: ......
Страница 235: ...Appendix E Ventilation Modes 223 APPENDIX E VENTILATION MODES...
Страница 236: ......
Страница 243: ...Appendix E Ventilation Modes 231 Notes...
Страница 244: ......
Страница 246: ......
Страница 252: ...240 Notes...
Страница 253: ...Appendix G Accessories 241 APPENDIX G ACCESSORIES...
Страница 254: ......
Страница 276: ...264 5 Fasten the external battery using the strap belt Figure 199 Connecting the Optional Battery Bag...
Страница 277: ...Appendix H Remote Alarm Connector 265 APPENDIX H REMOTE ALARM CONNECTOR...
Страница 278: ......
Страница 280: ......
Страница 281: ...Appendix I Part Numbers and Accessories 269 APPENDIX I PART NUMBERS AND ACCESSORIES...
Страница 282: ......
Страница 286: ...274...
Страница 289: ...Index 277...