97
Advent Commercial Fire System
Table B.4 Panel House Code Defaults/Settings for 4
Partition Panels
Partition
/Area
Panel House Code
Defaults
(HC1, HC2)
X10 House
Dial
House
Code
X10
House
Dial
1
HC1 = 1
HC2 = 5
A
E
____
____
____
____
2
HC1 = 2
HC2 = 6
B
F
____
____
____
____
3
HC1 = 3
HC2 = 7
C
G
____
____
____
____
4
HC1 = 4
HC2 = 8
D
H
____
____
____
____
Table B.5 Panel House Code Defaults/Settings for 8
Partition Panels
Partition
/Area
Panel House Code
Defaults
(HC1, HC2)
X10 House
Dial
House
Code
X10
House
Dial
1
HC1 = 1
HC2 = 9
A
I
____
____
____
____
2
HC1 = 2
HC2 = 10
B
J
____
____
____
____
3
HC1 = 3
HC2 = 11
C
K
____
____
____
____
4
HC1 = 4
HC2 = 12
D
L
____
____
____
____
5
HC1 (CB, CF) = 5
HC2 (CB, CF) = 13
E
M
____
____
____
____
6
HC1 (CB, CF) = 6
HC2 (CB, CF) = 14
F
N
____
____
____
____
7
HC1 (CB, CF) =7
HC2 (CB, CF) = 15
G
O
____
____
____
____
8
HC1 (CB, CF) = 8
HC2 (CB, CF) = 16
H
P
____
____
____
____
Table B.6 X10 Module Operation
Condition
Lamp Module
Unit No. 1
Lamp Module
Unit Nos. 2–16
Appliance/
Universal
Module Unit
Nos. 2–16
On entry delay
On for 5
minutes
Unchanged
Unchanged
On Fire Alarm* On
On
Unchanged
On Police
Alarm*
On
On
Unchanged
On Auxiliary
Alarm*
On
On
Unchanged
Lights On
On
On
Unchanged
Lights Off
Off
Off
Off
* Fire alarms have priority over both police and auxiliary
alarms. Police alarms have priority over auxiliary alarms.