Advent Commercial Fire System
Central Station Burglar-Alarm System Units (UL 1610)
System Setup and Programming
The system Feature Numbers shall be set as follows in
UL 1610 listed systems:
Digital Alarm Communicator System Units (UL 1635)
Same as UL 1610 plus:
A UL Listed Exterior Siren
Central Station Reporting
The panel has been tested with the following central station
receivers using Contact ID reporting format:
ITI CS-5000 Central Station Receiver
Sur-Gard Central Station Receiver with models
SG-DRL2A and SG-CPM2
CSA Certified Accessories
California State Fire Marshall Listed
Installations
The California State Fire Marshall listing has been
approved.
ZONE ATTRIBUTES attribute 4 must be set to off
(47004)
Planning the Installation
This section describes system capabilities to help you get
familiar with the system. “Appendix A” provides planning
sheets with tables that let you record the hardware and pro-
gramming configuration of the system. Fill in all necessary
information ahead of time to help prepare for the installa-
tion, and retain for your records.
Note
It is recommended that no more than 250 wireless fire
sensors (60-849-01-95 or 60-917-95 only) and a maxi-
mum of 132 of all other wireless sensors be used on 250
zone Advent systems.
If 2 Advent systems are in close proximity the total number
of wireless sensors for all systems must not exceed 250
wireless fire sensors or 132 of all other sensors.
Panel Types
To start planing the installation, find your specific panel
type below. The panel type will help determine the system
capabilities (dependent upon devices used).
Panel Components
Before installing devices and making wiring connections,
familiarize yourself with the main panel components. Fig-
ure 1 shows the main component locations for the circuit
board.
47004
Zone Attributes (edit sensors) N/A
xx = Two digit partition number.
yy = Two digit non-pager phone number.
Table 6. UL 1610 Listed System Settings
Feature No.
Feature
Required Setting
xx002
Siren Time Out
16 min., minimum
xx003
Standard Entry Delay
45 sec., maximum
xx004
Exit Delay
60 sec., maximum
yy004
Communication Format
0 Contact ID
xx088
Report Partition/Area Events
to Central Station
1-On
xx092
Enable Auto Force Arming
0-Off
xx097
Exterior Arming Verification 0-Off
xx098
Audible Verification at Close
Report
1-On
xx102
One-Time Reset Enabled
0-Off
xx108
Enable Daily Reporting of
Partition Trouble
1-On
17034
Phone Test Interval
1 Day
17036
AC Stable Time
90 sec. maximum
17041
Hours to Delay Before
Reporting AC Failure
6-12 hours
17049
RF Supervisory Time A
4 hours
17069
No Phone Line Attached
0-Off
17072
Enable RF Jam Detect
1-On
17073
Battery Test Interval
1-4 hours
17076
Commercial or Residential
Installation
1-Commercial
17078
Detect Receiver Failure
1-On
17079
Alarm Messages Play at High
Volume
1-On High
17096
Report System Events
1-On
47004
Zone Attributes (edit zones)
N/A
xx = Two digit partition number.
yy = Two digit non-pager phone number.
Table 5. UL 1023 Listed System Settings
Feature No.
Feature
Required Setting
Table 7. Advent Commercial Panel Types
Part Number
Description
Pa
rt
iti
o
ns
/Are
a
s
Us
e
rs
In
put
Z
one
s
LEDs
250Z, 60-562-03
Commercial Fire
Panel. UL Listings
include 864, 365, 609,
985, 1023, 1610, and
1635. Red enclosure.
8
250 250 512
132Z, 60-562-06
4
100 132 256