![GE 60000 Series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/ge/60000-series/60000-series_installation-and-start-up-manual_4074671020.webp)
20
Fuel Consumption
Estimated fuel supply requirements at half and full load for
natural gas and LP vapor fuels are shown here.
Physical
Properties
LP Vapor
Natural
Gas
Normal Atmospheric
State
Gas
Gas
Boiling Point (in °F):
Initial
End
-44
-44
-259
-259
Heating Value:
BTU per gallon (Net
LHV*)
BTU per gallon (gross**)
Cubic feet (gas)
83,340
91,547
2,500
63,310
1,000
Density***
36.39
57.75
Weight†
4.24
2.65
Octane Number:
Research
Motor
110+
97
110+
*
LHV (Low Heat Value) is the more realistic rating.
** Gross heat value does not consider heat lost in the form of water during
combustion.
*** Density is given in “Cubic Feet of Gas per Gallon of Liquid”.
†
Weight is given in “Pounds per Gallon of Liquid”.
60kW LP Vapor Fuel Consumption
Full Load
1/2 Load
Exercise
BTU/hr
862500
500000
207500
CF/ph
345
200
83
m³/ph
9.8
5.7
2.4
GAL/hr
9.0
5.2
2.2
55kW Natural Gas Fuel Consumption
Full Load
1/2 Load
Exercise
BTU/hr
788000
463000
217000
CF/ph
788
463
217
m³/ph
22.3
13.1
6.2
NOT
for
REPRODUCTION
Содержание 60000 Series
Страница 28: ...28 Schematic Diagram Page 29 Page 31 Page 33 Page 30 Page 32 Page 34 N O T f o r R E P R O D U C T I O N...
Страница 31: ...31 Schematic Diagram continued YEL 18 BLK 18 GRY 20 YEL 18 BLK 14 N O T f o r R E P R O D U C T I O N...
Страница 33: ...33 Schematic Diagram continued GRY 20 YEL 18 GRN 20 YEL 20 BLK 14 N O T f o r R E P R O D U C T I O N...
Страница 35: ...35 N O T f o r R E P R O D U C T I O N...
Страница 36: ...36 Wiring Diagram ComAp InteliNano Control Panel N O T f o r R E P R O D U C T I O N...
Страница 37: ...37 Wiring Diagram ComAp InteliNano Control Panel N O T f o r R E P R O D U C T I O N...
Страница 38: ...38 Wiring Diagram ComAp InteliLite Control Panel N O T f o r R E P R O D U C T I O N...
Страница 39: ...39 Wiring Diagram ComAp InteliLite Control Panel N O T f o r R E P R O D U C T I O N...