CyScan Positioning System • Installation and Maintenance Guide r1.1
GCS
GCS
Wiring the CyScan System
The CyScan system introduces four main items to the vessel, these are:
• CyScan Sensor
• Power Supply Unit
• Data Converter
• CyScan Console Notebook Computer
The diagram below indicates the connections between the four items.
1
2
3
4
5
6
7
8
9
10
11
12
3
13
14
15
16
17
18
19
20
21
3
22
22
22
22
23
23
23
23
3
Console
DP
Power
2TX
2RX
1TX
1RX
PW
R
Power
CyScan
Sensor
Power
Supply
Unit
Data
Converter
DP Feed
Console Feed
To
DP Unit
Main
Power In
CyScan
Console
notebook
computer
Power Supply Unit (PSU)
The PSU is supplied with three flying leads, all of which attach to the connectors at the
Stern end of the sensor. Three M20 x 1.5 threaded holes (fitted with stopping plugs) are
provided to accommodate cable glands leading to/from:
• The vessel’s DP system
• The CyScan notebook computer (via the Data Converter)
• A suitable AC power feed
Inside, the PSU contains a row of industrial connectors to make the wiring process as
quick and flexible as possible. Each connector is numbered and the relevant signal con-
nections (with their connector number) are shown on the diagram (overleaf). The PSU
requires a supply of 90-264VAC at 5A.