GatesAir
4-1
Intraplex Products
Section 4 – Remote Configuration & Operation
This section discusses remote control configuration and operation, which allows you to control the PT-
353 and PR-353 modules, as well as other Intraplex modules and shelves, from a central location
using one of these features:
●
IntraGuide Configuration and Management Software
–Windows
®
-based software you can
use to configure and monitor multiple Intraplex systems from one control point. The IntraGuide
gives complete details on using this software. Section 4.2 –
IntraGuide Software
gives several of
the IntraGuide screens that pertain to these modules.
●
NetXpress Web Browser Interface
– When these modules are installed in a NetXpress
multiplexer, they can be controlled by the NetXpress Web browser interface, as the
NetXpress
Installation & Operation Manual
describes.
●
ISiCL
– Intraplex Simple Remote Control Language; a command-line interface from a PC or dumb
terminal. With ISiCL, you can set the module’s operating parameters and make status and
configuration inquiries. ISiCL can also be used for control by a higher-level network management
system (NMS). Your Intraplex multiplexer operating manual gives details on using ISiCL remote
control commands. Section 4.3 –
ISiCL Interface
describes the ISiCL commands that are particular
to the PT-353 and PR-353 modules.
4.1 Remote Configuration
In order to configure the PT-353 and PR-353 modules remotely, you must physically set the module
switches to remote control. Perform these steps:
1.
Set the REMOTE switch to local control (SW3 Position 3 UP – PT-353 and PR-353 – Table 3-5).
2.
Turn service off (SW3 Position 4 DOWN – PT-353 and PR-353).
3.
Install the module.
4.
Wait 15 seconds for the module’s parameter settings to load into the shelf common module.
5.
Remove the module and turn the REMOTE switch on (SW3 Position 3 DOWN – PT-353 and PR-
353). Do not turn the service on.
6.
Reinstall the module.
7.
Verify the configuration via remote control by issuing a CONFIG? command, which is
accomplished by entering this command structure:
<Address>:<SCBaddress>:CONFIG?:;
For example, :C1:CONFIG?:; calls to SCB address number 1. The card configuration in the address
is returned. (Table 4-1 shows a sample response.)
Table 4-1. Sample PT-353 Response to CONFIG? Query
Response
Meaning
*OK
CHANNEL CARD 8, TYPE 116
UNDER REMOTE CONTROL
SRVC = OFF
P01 = 1 (B00000001)
P02 = 99 (B01100011)
P03 = 1 (B00000001)
P04 = 1 (B00000001);
P05 = 1 (B00000000);
Valid command received
Module SCB address 8 is a PT-353 module
Remote control is on
Service is off
P01: Starting time slot is 1
P02: See below b
P03: Set for DI/B port
P04: PAD off, ASRC is on
P05: Not used
Содержание PT-353
Страница 2: ......
Страница 10: ...No header here 1 2 GatesAir Intraplex Products This page is left blank intentionally...
Страница 30: ...No header here 3 16 GatesAir Intraplex Products This page is left blank intentionally...
Страница 46: ...No header here 5 4 GatesAir Intraplex Products This page is left blank intentionally...
Страница 50: ...No header here 6 4 GatesAir Intraplex Products This page is left blank intentionally...