PT/PR-353 Program Audio Module Installation & Operation Manual
3 – Installation & Operation
Version 1.1
3-14
GatesAir
Intraplex Products
Table 3-7. PT-353 and PR-353 Indicator Lights
Indicator
Light
Function
Color
Status
When lit, it indicates
B
o
th
P
T
-353
an
d
P
R
-353
M
o
d
u
les
SRVC*
Service Indicator
Green
Off
Module is disabled.
Blinks
Blinks if a configuration error is present.
On
Service for the module is ON.
LEVELS
Level Indicator 1
Green
On
Signal strength is -4 dBm (-24 dBFS).
Level Indicator 2
Green
On
Signal strength is +2 dBm (-18 dBFS).
Level Indicator 3
Green
On
Signal strength is +8 dBm (-12 dBFS).
Level Indicator 4
Yellow
On
Signal strength is +14 dBm (-6 dBFS).
Overload
Indicator
Red
On
Signal strength is ≥ +20 dBm (0 dBFS).
2MB
TDM Timing
Detector
Green
Off
T1 bus (1.544 mHz)
On
2MB bus (2.048 mHz)
FAIL*
Fail Indicator
Red
Off
Normal
On
Hardware or software failure (An ALARM signal is
sent to the multiplexer common module if this
indicator light is on.)
PT
-353
M
o
du
le
O
n
ly
DIG
Audio Source
Green
Off
Analog source detected (or no source detected).
Blinks
Input data rate does not match the board rate.
On
Digital source detected.
AUX
Auxiliary Data
Overflow
Yellow
Off
Normal position
Flash
Erratic flickering – Incoming serial auxiliary data
exceeds available transmission bandwidth.
ERR
Bit Error
Yellow
Off
Digital source detected.
Flash
Erratic flickering – (for .1 second) Bit errors
detected.
PR
-353
M
o
du
le
O
n
ly
ACT
TDM Data
Activity
Green
Off
Received data is all zeros or all ones.
On
Received data is a mix of zeros and ones.
FRAME
FEC Frame
Green
Off
Module is out of frame.
On
Module is in frame.
ERR
Bit Error
Yellow
Off
No errors detected.
Flash
Erratic flickering – (for .1 second) Bit errors
detected.
On
Three or more consecutive 8-frame blocks have
errors. Audio is muted (faded to zero over a period
of 1-2 ms) until three consecutive error-free 8-
frame blocks are detected.
3.6 Impedance
Terminal impedance can be set on the PT-353 module using Jumper 3 and Jumper 4. Terminal
impedance is used to match impedance between the PT-353 module and the PR-353 module to ensure
that input and output are equivalent. Table 3-8 gives the audio input impedance jumpers for the PT-
353 module.
Содержание PT-353
Страница 2: ......
Страница 10: ...No header here 1 2 GatesAir Intraplex Products This page is left blank intentionally...
Страница 30: ...No header here 3 16 GatesAir Intraplex Products This page is left blank intentionally...
Страница 46: ...No header here 5 4 GatesAir Intraplex Products This page is left blank intentionally...
Страница 50: ...No header here 6 4 GatesAir Intraplex Products This page is left blank intentionally...