13-17-621 Page 145
P.101
Fault
separator
temperature
high fault
Separator temperature
has exceeded the high
fault limit setting.
Check the condition of compressor cooling
functions such as thermal mixing valve and
cooler. Check oil condition and oil level. Examine
airend for issues. Review history of compressor
discharge temperature using the controller trends,
data logs, or site maintenance log. Perform
adjustments, cleaning, or repair based on the
results of the investigation.
P.101
Warning
separator
temperature
high warning
Separator temperature
has exceeded the high
warning limit, nearing the
fault limit.
Check the condition of compressor cooling
functions such as thermal mixing valve and
cooler. Check oil condition and oil level. Examine
airend for issues. Review history of compressor
discharge temperature using the controller trends,
data logs, or site maintenance log. Perform
adjustments, cleaning, or repair based on the
results of the investigation.
P.102
Fault
separator
temperature low
fault
Separator temperature is
below the low fault limit
setting.
Increase the ambient temperature near the inlet
to the compressor package.
P.102
Warning
separator
temperature low
warning
Separator temperature is
below the low warning
limit, nearing the fault
limit.
Increase the ambient temperature near the inlet
to the compressor package.
P.103
Fault
separator
temperature
short fault
Separator temperature
sensor is faulty, or the
wiring to the sensor is
shorted.
Using the wiring schematic for the machine,
locate the separator temperature sensor
connection to the controller. Check for any
shorted wires at the connector. Inspect the cable
for damage between the controller and the
sensor. Remove the cable connector from the
sensor and use a multi-meter to check the
resistance of the sensor and ensure that it is not
shorted. It is possible that the sensor may read
within range at room temperature but still be
faulty once exposed to an elevated temperature
or vibration. Replace or repair the wiring or
sensor as needed.
P.104
Fault
separator
temperature
open fault
Separator temperature
sensor is faulty, or the
connection between the
sensor and controller is
disconnected.
Using the wiring schematic for the machine,
locate the separator temperature sensor
connection to the controller. Check for
disconnected wires, plugs, or loose connections.
Inspect the cable for damage between the
controller and the sensor. Remove the cable
connector from the sensor and use a multi-meter
to check the resistance of the sensor and ensure
that it is not open (very high resistance) It is
possible that the sensor may read within range at
room temperature but still be faulty once exposed
to an elevated temperature or vibration. Replace
or repair the wiring or sensor as needed.
P.105
Fault
Ambient
temperature
high fault
Ambient air temperature
is too high to start or run
the compressor.
Check the site conditions and decrease
temperature of the ambient air to the compressor
enclosure.
P.105
Warning
Ambient
temperature
high warning
Ambient air temperature
is approaching the
maximum limit to start or
run the compressor.
Check the site conditions and decrease
temperature of the ambient air to the compressor
enclosure.
P.106
Fault
Ambient
temperature low
fault
Ambient air temperature
is too low to start or run
the compressor.
Check the site conditions and increase
temperature of the ambient air to the compressor
enclosure.
Содержание Governor TEN014980
Страница 12: ...13 17 621 Page 12 Figure 4 Oblique View Figure 5 Rear View ...
Страница 165: ...13 17 621 Page 165 Figure 176 Sequencing Diagnostics ES Protocol Figure 177 Sequencing Diagnostics AirSmart Protocol ...
Страница 188: ...13 17 621 Page 188 Figure 217 VFD Diagnostics Figure 218 VFD Diagnostics ...
Страница 193: ...13 17 621 Page 193 Page left blank intentionally ...