13-17-621 Page 105
Figure 144: Control - Default
4.7.3.1 Automatic Stop Time:
The
Automatic Stop Time
is the amount of time that the compressor will run after the blowdown timer has
expired before stopping the motor. This time setting has two inputs, one is for Minute and other for Seconds.
Figure 145 below shows the setting
Automatic Stop Time
to
5 min 0 Sec
.
Figure 145: Automatic Stop Time
4.7.3.2 Rotation Direction Check:
The
Rotation Direction Check
setting can be set to either
On
or
Off
by using the On/Off toggle Button.
When the
Rotation Direction Check
is enabled, the controller will for pressure to be built in the reservoir
immediately following the motor starting, if adequate pressure is not detected the unit will be shut down on
a no start pressure fault. This may indicate that the motor is turning the wrong direction. In some
Содержание Governor TEN014980