GARDTEC
800 Series
Miscellaneous
Appendix 1
Using Point ID
The ProDigi Communicator or Gardtec
800 Series
Modem from Gardiner Technology
may, if required be used to allow Point ID communication with the Gardtec 840. When
used in this mode the ProDigi/Modem will use the Ademco Point ID Protocol.
Point ID allows for the transmission of zone and detector types to be transmitted along
with the alarm information. This qualifies as sequential verification as recommended by
the 1995 ACPO policy.
To use Point ID the ProDigi/Modem should be connected to the Gardtec
840
via the
serial lead that is supplied with it (this is shown in Fig 16 on page 25).
To use the communicator in Point ID mode and program the relevant functions, the
control panel needs to be told that it is to use the ProDigi as a Point ID communicator.
This is done via option 34 in the engineer options (Digicom Type), which should be
changed to:-
Digicom Type.....
= Point ID or Mod+PID for the Modem
If using an LED type keypad to select Point ID:-
With the display showing E- press 34 followed by YES
Then press NO 03 (or 04 for Modem) followed by YES
It should be noted that although you are able to turn on the Point ID function via an
LED keypad you will not be able to program the Digicom functions unless you are
working via an LCD keypad. This allows for a pre-programmed ProDigi to be fitted onto
an existing system with LED only keypads.
When using the ProDigi or Modem with the Gardtec
800 Series
control panel you
will be able to use the ProDigi as a Point ID communicator or fast format
communicator. It is not possible to use both formats at the same time.
GARDTEC
800 Series
Miscellaneous
Engineer Reset After An Alarm
If a system is programmed for engineer reset it will be necessary for the engineer to
attend the system. After the engineer has confirmed the integrity system the system
should be reset as follows:-
1)
After the system has been Unset, enter the
engineer code, the display will show:-
2)
Press NO, the display will show:-
3)
Press YES, the display will show:-
4)
Enter the engineer code again to abort the
setting, the display will show:-
5)
The system is now Unset.
< < < < UN-SET > > > >
01 Jan 00: 00: 01
Do you want to . .
Use ENGNR. Mode ?
Do you want to . .
SET the System ?
Exit Now ! 1 2 3 C