GARDTEC
800 Series
Programming
Option No/
Description
Default
Gardtec
800 Series Programming Guide
Available Options
84
Timer 2
Turn On
Time (Hrs)
00
Hours
(00)
00 - 23 Hrs
GARDTEC
800 Series
Programming
Option No/
Description
Default
Gardtec
800 Series Programming Guide
Available Options
74
Map ID
Devices On
SAD 2
Press YES to Auto-Map Devices on SAD2
Press NO to Manually Map Devices on SAD2
75
ZEX 1
Wiring
Off
(03)
(00) 4 (4Wire)
(01) 8 (EOL)
(02) 8 (2 Wire)
(03) Off
Note: This option determines the wiring method for ZEX 1.
Each ZEX may use a different wiring method.
If 840 Zex ensure correct ident is selected on the ZEX
76
ZEX 2
Wiring
Off
(03)
(00) 4 (4Wire)
(01) 8 (EOL)
(02) 8 (2 Wire)
(03) Off
Note: This option determines the wiring method for ZEX 2.
Each ZEX may use a different wiring method.
If 840 Zex ensure correct ident is selected on the ZEX
77
ZEX 3
Wiring
Off
(03)
(00) 4 (4Wire)
(01) 8 (EOL)
(02) 8 (2 Wire)
(03) Off
Note: This option determines the wiring method for ZEX 3.
Each ZEX may use a different wiring method.
Ensure correct ident is selected on the ZEX
78
ZEX 4
Wiring
Off
(03)
(00) 4 (4Wire)
(01) 8 (EOL)
(02) 8 (2 Wire)
(03) Off
Note: This option determines the wiring method for ZEX 4.
Each ZEX may use a different wiring method.
Ensure correct ident is selected on the ZEX
79
ZEX 5
Wiring
Off
(03)
(00) 4 (4Wire)
(01) 8 (EOL)
(02) 8 (2 Wire)
(03) Off
Note: This option determines the wiring method for ZEX 5.
Each ZEX may use a different wiring method.
Ensure correct ident is selected on the ZEX
80
ZEX 6
Wiring
Off
(03)
(00) 4 (4Wire)
(01) 8 (EOL)
(02) 8 (2 Wire)
(03) Off
Note: This option determines the wiring method for ZEX 6.
Each ZEX may use a different wiring method.
Ensure correct ident is selected on the ZEX
81
ZEX 7
Wiring
Off
(03)
(00) 4 (4Wire)
(01) 8 (EOL)
(02) 8 (2 Wire)
(03) Off
Note: This option determines the wiring method for ZEX 7.
Each ZEX may use a different wiring method.
Ensure correct ident is selected on the ZEX
82
ZEX 8
Wiring
Off
(03)
(00) 4 (4Wire)
(01) 8 (EOL)
(02) 8 (2 Wire)
(03) Off
Note: This option determines the wiring method for ZEX 8.
Each ZEX may use a different wiring method.
Ensure correct ident is selected on the ZEX
(800 & 816
options are
referred
from options
1 & 44)
83
Output
Expander
Modes (840)
For LED
Prompt is n-
Enter output
No. 1-16 then
YES. To
change
setting press
NO then
enter new
setting then
YES
For LCD
Press NO
Choose area
option then
use NO to
scroll to
required
setting.
Various
dependant
on option
(00) Pulse-Off
(01) Pulse-On
(02 Set)
(03) Alarm
(04) After Alarm
(05) Unset
(06) Pulse-On-Set
(07) Part-Set
(08) Walk-Test
(09) Mains Fail
(10) Bell
(11) Strobe
(12) Latch
(13) Any Digi
(14) Int. Sndr
(15) E/E
(16) Timed On/Off
(17) Alert
(18) Alarm-B
(19) Alarm Abort
(20) Fire
(21) Panic
(22) Gen. Tamper
(23) Zone Tamper
(24) Power-Fail
(25) Watchdog
(26) Set Cleaner
(27) O/C Cleaner
(28) Any Closed
(29) Off
A1
(00) Off
(04) Latch A1
(12) Pulse Off A1
(16) Pulse On A1
(20) Set A1
(29) After Alarm A1
(37) Walktest A1
(74) Part Set A1
(41) Pulse @ Set A1
(55) Int Sounder A1
(44) E/E A1
(75) Bell A1
(76) Zone Alert A1
(77) Fire Zone A1
(78) Panic Zone A1
(33) O/C A1
(25) Alarm A1
(48) Alarm B A1
(52) Alarm Abort A1
(79) Zone Tamper A1
A2
(00) Off
(05) Latch A2
(13) Pulse Off A2
(17) Pulse On A2
(21) Set A2
(30) After Alarm A2
(38) Walktest A2
(80) Part Set A2
(42) Pulse @ Set A2
(56) Int Sounder A2
(45) E/E A2
(81) Bell A2
(82) Zone Alert A2
(83) Fire Zone A2
(84) Panic Zone A2
(32) O/C A2
(26) Alarm A2
(49) Alarm B A2
(53) Alarm Abort A2
(85) Zone Tamper A2
A3
(00) Off
(06) Latch A3
(14) Pulse Off A3
(18) Pulse On A3
(22) Set A3
(31) After Alarm A3
(39) Walktest A3
(86) Part Set A3
(43) Pulse @ Set A3
(57) Int Sounder A3
(46) E/E A3
(87) Bell A3
(88) Zone Alert A3
(89) Fire Zone A3
(90) Panic Zone A3
(35) O/C A3
(27) Alarm A3
(50) Alarm B A3
(54) Alarm Abort A3
(91) Zone Tamper A3
All
(00) Off
(60) Closed All
(61) Alarm All
(62) Alarm B All
(63) Abort All
Any (00) Off
(09) Timed 1
(58) Timed 2
(59) Timed 3
(73) Closed Any
(11) Pulse Off
(15) Pulse On
(28) After Alarm
(36) Walktest
(40) Pulse @ Set
(07) Int Sounder
(08) E/E
(01) Bell
(10) Alert
(64) Any fire
(65) Any Panic
(24) Alarm
(47) Alarm B
(51) Alarm Abort
(66) O/C Cleaner
(23) Set Cleaner
(67) General Tamper (68) Zone Tamper
(69) Part Set
(02) Strobe
(03) Any Latch
(19) Any Set
(70) Power Fail
(71) Watchdog
(72) Mains Fail