![GARDINER TECHNOLOGY Gardtec 800 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/gardiner-technology/gardtec-800/gardtec-800_installation-instructions-manual_3550421032.webp)
Page
61
Page
60
*1Note: With LCD this option will appear the same as option 51
*2Note: With LCD chime is via the Part/Test/Chime option 52.
GARDTEC
800 Series
Programming
Option No/
Description
Default
Gardtec
800 Series Programming Guide
Available Options
65
Digi
Test Mode
Once in test mode with LCD display will show the number of channels
available press the corresponding number keys to activate and again to
restore, (the number of channels shown is dependant on the type of
communicator programmed e.g 4 for Normal Digi, 8 for Modem or ProDigi
Once in test mode with LED display will show C- press the number keys
corresponding to the desired channel to activate and again to restore.
Note: No access to test mode with an outstanding Alarm
Note: With both types of display use the 0 key to escape test mode.
66
Entry/Exit
Zone in
Part Set
Entry/Exit
in Part Set
(00)
(00) Entry/Exit zones are Entry/Exit in Part Set
(01) Entry/Exit zones are 12Hr in Part Set
This option determines how ALL E/E zones will act in Part-Set(s)
67
Engineer
Code
Lock-In
Unlocked
(00)
(00) Unlocked
(01) Locked
Note: Caution should be used with this option, once the engineer
code has been locked-in it may only be unlocked/changed by use
of the programmed code.
DEFAULTING THE PANEL WILL NOT UNLOCK THE CODE.
68
Strobe
Setting
Conformation
Off
(00)
(00) Off
(01) Full Set Only
(03) Any Set
Note: If this option is used the strobe will confirm the final setting of the
system.
69
Auto
Part Set
Off
(00)
(00) Off
(01) On
Note: To use this option the setting mode must be programmed to Time +
E/E. If the E/E door is opened/closed during the exit period the system
will full set, if not the system will part set 1.
70
Part Set
Bells
(01)
On
(00) Off
(01) On
Note: If part set bells are programmed to OFF no bell output will be given
when the system is PART-SET.
71
Area
Programming
Chime &
Forced Walk
Test
Allocation
For LED
Only
Displays
Area 1
FWT Off
Chime Off
(00)
(Left Digit LED)*1
(0) Area 1
(1) Area 2
(2) Areas 1+2
(3) Area 3
(4) Areas 1+3
(5) Areas 2+3
(6) Areas 1+2+3
(Right Digit LED)*2
(0) FWT Off - Chime Off
(1) FWT Off - Chime On
(2) FWT On - Chime Off
(3) FWT On - Chime On
72
Zone
Expansion
Type
816 ZEX
(00)
ZEX
(00)
(00) 816 ZEX
(01) 840 ZEX
Note: 816 may use 816 or 840 Zone Expanders
(00) 840 ZEX
(01) ID
Note: 840 may use 840 or ID Zone Expanders
73
Map ID
Devices On
SAD 1
Press YES to Auto-Map Devices on SAD1
Press NO to Manually Map Devices on SAD1
GARDTEC
800 Series
Programming
53
Service
Timer
Off
(00)
(00) Off
(01) On
This option should be used in conjunction with option 54
Option No/
Description
Default
Gardtec
800 Series Programming Guide
Available Options
54
No. Weeks
to Service
00
Weeks
(00)
00 - 99 Weeks
This option should be used in conjunction with option 53
55
Zone
Log Limit
On
(01)
(00) Off
(01) On
56
Enable Alert
1 Keys 1&3
Off
(00)
(00) Off
(01) On
Note: Use option 20 to select mode of Alert 1 Keys
57
Enable Alert
2 Keys 7&9
Off
(00)
(00) Off
(01) On
Note: Use option 21 to select mode of Alert 1 Keys
58
Digi Channel
1 Mode
Off
(00)
As Option 31 (D1 Output Mode)
For LCD use YES key to move to desired channel and the NO key to
change the setting for the selected channel.
59
Digi Channel
4 Mode
(00)
Off
As Option 31 (D1 Output Mode)
For LCD use YES key to move to desired channel and the NO key to
change the setting for the selected channel.
60
Digi Channel
5 Mode
Off
(00)
As Option 31 (D1 Output Mode)
For LCD use YES key to move to desired channel and the NO key to
change the setting for the selected channel.
61
Digi Channel
6 Mode
Off
(00)
As Option 31 (D1 Output Mode)
For LCD use YES key to move to desired channel and the NO key to
change the setting for the selected channel.
62
Digi Channel
7 Mode
Off
(00)
As Option 31 (D1 Output Mode)
For LCD use YES key to move to desired channel and the NO key to
change the setting for the selected channel.
63
Digi Channel
8 Mode
Off
(00)
As Option 31 (D1 Output Mode)
For LCD use YES key to move to desired channel and the NO key to
change the setting for the selected channel.
64
Comms in
Part Alrm/
Restore/
Abort
Restore Off
Part Alrm
Comms On
Abort=60
Secs
(23)
(Left Digit LED)
(Right Digit LED) Abort Time
(0) Restore Off / Part Alarm Comms Off
0 - 9 x 20 Secs
(1) Restore On / Part Alarm Comms Off
e.g 1=20 Secs 2=40 Secs...........
(2) Restore Off / Part Alarm Comms On
(3) Restore On / Part Alarm Comms On
4344R12.qxd 03/09/99 11:09 Page 60