GARDTEC
800 Series
Programming
Option No/
Description
Default
Gardtec
800 Series Programming Guide
Available Options
23
No. Of
Bell Arms
99
Activations
(99)
00 - 99 Activations
Note: If this option is programmed to 0 the Bell will not activate
24
[Area1] Bell
Ring Time
20
Minutes
(20)
00 - 99 Minutes
Note: If this option is programmed to 0 the Bell will not activate
Note: Local environmental legislation should be checked
25
[Area1] Bell
Delay Time
00
Minutes
(00)
00 - 99 Minutes
Note: Bell delay is overridden in the event of a linefault
26
Bell
Type
SAB
(01)
(00) SCB
(01) SAB
Note: All Gardiner Technology Bell Boxes (including SCB types) should
use the (01) SAB setting.
27
Bell Tamper
Ring
On
(01)
(00) Off
(01) On
28
Entry
Time 1
30
Seconds
(30)
00 - 99 Seconds
29
Entry
Time 2
10
Seconds
(10)
00 - 99 Seconds
30
Digi
Start Delay
00
Seconds
(00)
00 - 99 Seconds
Note: Digi Start Delay applies to Part Set system
31
D1 Output
Mode
Off
(00)
(00) Off
(01) Zone Tamper
(02) General Tamper
(03) Alert
(04) Fire
(05) Part-Set
(06) Open/Close
(07) Panic
(08) Alarm
(09) Alarm B
(10) Alarm Abort
(11) 12V Power Fail
(12) Watchdog
(13) Mains Fail
(14) Area 1 Alarm
(15) Area 2 Alarm (16) Area 3 Alarm
(17) O/C Area 1
(18) O/C Area 2
(19) O/C Area 3
(20) O/C Cleaner
(21) Alrm B Area1 (22) Alarm B Area2
(23) Alarm B Area 3
(24) Alrm Abort A1(25) Alarm Abort A2
(26) Alarm Abort A3
(27) Panic Area 1 (28) Panic Area 2
(29) Panic Area 3
(30) Fire Area 1
(31) Fire Area 2
(32 Fire Area 3
32
D2 Output
Mode
Off
(00)
As D1 Output Mode (Option 31)
33
Digi Output
Start
Negative
Start
(01)
(00) Positive Start (01) Negative Start
Note: All Digi outputs (including D1 D2) are open collector outputs with
10 Ohm resistor in series, some Digis may require 6K8 pullups
GARDTEC
800 Series
Programming
11
Final Set
Delay
03
Seconds
(03)
00 - 99 Seconds
Option No/
Description
Default
Gardtec
800 Series Programming Guide
Available Options
12
[A1] Full Set
Exit Time
30
Seconds
(30)
00 - 99 Seconds
13
[A1] Part1
Exit Time
30
Seconds
(30)
00 - 99 Seconds
14
[A1] Part2
Exit Time
30
Seconds
(30)
00 - 99 Seconds
15
[A1] Part3
Exit Time
30
Seconds
(30)
00 - 99 Seconds
16
[A1] Full Set
Mode
Time
(03)
(00) Exit Terminator Button
(01) Entry/Exit Door
(02) Time + Entry/Exit Door
(03) Time
17
[A1] Part1
Set Mode
Time
(03)
(00) Exit Terminator Button
(01) Entry/Exit Door
(02) Time + Entry/Exit Door
(03) Time
18
[A1] Part2
Set Mode
Time
(03)
(00) Exit Terminator Button
(01) Entry/Exit Door
(02) Time + Entry/Exit Door
(03) Time
19
[A1] Part3
Set Mode
Time
(03)
(00) Exit Terminator Button
(01) Entry/Exit Door
(02) Time + Entry/Exit Door
(03) Time
20
Alert 1
Mode
Off
(03)
(00) Fire
(01) P.A
(02) Alert
(03) Off
Note: This feature must be enabled using option No.56
21
Alert 2
Mode
Off
(03)
(00) Fire
(01) P.A
(02) Alert
(03) Off
Note: This feature must be enabled using option No.57
22
Keyswitch/
No of RKPs
No K/S
1 Keypad
(01)
(Left Digit LED)
(Right Digit LED)
(00) No Keyswitch
1 - 4 Number of Keypads
(01) Biased Keyswitch
(02) Normal Keyswitch
(03) Locked
4344R12.qxd 03/09/99 11:09 Page 56