Fig. 16 ProDigi or Gardtec
840
Modem Wiring.
Note:
Modem will give 8 channels and leave D1, D2 & D3 (PA term) free for
other uses
For a ProDigi program Digicom Type to Gardiner
For Modem Mod+FF or MOD+PID
Remove link from 12V & Line Fault Terminals before connecting
ProDigi/Modem
Both the ProDigi and Gardtec Modem can be programmed direct from the
Gardtec
840
Modem Patch Lead
If the Gardtec
800 Series
Modem patch lead is to be used for direct connection to a PC
or Lap-Top It should be connected to SK3. The factory fitted link between 12V &
Line Fault must be removed. Full instructions on use of the Gardtec
800 Series
Modem Patch lead are supplied with the unit.
Gardtec 840
Main PCB
Communicator
SK3
ProDigi
or
Gardtec Modem
Gardtec
840
Main PCB
If the Gardtec Modem is
used basic system
configuration is available by
defaulting the system using
5, 5, YES, NO. Further
details are given in the
Gardtec Modem manual.
Page
26
D1 & D2
These terminals are digicom outputs that are fully programmable by the engineer (see
Programmable Options Description for more details). The outputs are open collector
and have a maximum current sink of 50mA*
1
*
2
. On systems only using two channels
or systems using the ProDigi or Modem D1 & D2 are free for other uses.
Note:
The start polarity is of the Digicom port is programmable by the
engineer.
Fig. 15 Typical Digicom Wiring
Note:
D1 should be programmed for FIRE
(Chan1)
D2 should be programmed for OPEN/CLOSE
(Chan4)
Program Digicom Type to NORMAL
6K8 resistors provide Pull-Up for open collector outputs
*
1
No attempt should be made to exceed the stated current and the 1 Amp
maximum current draw from the control panel must be taken into consideration.
*
2
Some Digicoms may require a 6K8 pull-up resistor fitting between this output
and 12V
6K8
6K8
6K8
6K8
0V 12V LINE PA 12HR D1 D2
FAULT ALARM
0V 12V 2 3 1 4
CHANNELS
Gardtec
840
For example
D.A.C 4 or
Red-Care
3GSTU
BLUE STU
Home STU
GARDTEC
800 Series
GARDTEC
800 Series
Wiring Connections
Wiring Connections