Zone Type Terminology
Each zone has a default type that may be re-programmed. Below is an explanation of
the terminology used for zone types.
12 Hour
Zone active when Control Panel is Set.
Access
Will allow to pass through on exit.
Will allow to pass through on entry only if E/E is opened first.
24 Hour
Internal Sounder if Unset.
Full alarm if Set.
Remains active in Engineer Programming Mode.
Entry/Exit (or E/E)
Zone used as last exit point (will terminate exit time if setting mode is set to
E/E or Time+E/E).
Will start E/E time if opened when Control Panel is Set
Part E/E
As Access if Control Panel is Full Set
As Entry/Exit if Control Panel is Part Set
Panic
24Hour Personal Attack (or Panic Attack). Active if Control Panel is Set,
Unset or in Engineer Programming Mode . May only be tested via Engineer
code if programmed as testable.
Alert
Internal Sounder Only, Recorded to Log when Unset
Recorded to Log when SET
Fire
Will give Fire alarm when activated (pulsed sounders) with Control Panel Set
or Unset.
Remains active in Engineer Programming Mode.
ET
Exit terminator. Used for final setting of the system. Exit Mode must be
programmed for ET or Time + ET.
Monitor
Will write to the log once only in any one set or unset unless chime is
allocated then all activations are written to the log.
GARDTEC
800 Series
Areas & Zones
The User codes that are allocated to the system shown in Fig. 35 are:-
User No.
User Type
Functions Available
1
Master
Set/Area Sets/Part Set/Unset
Remove Zones
Test Zones
View Log
Change Chime
Change User Codes
Change Time/Date
2
Area 1
Set/Part Set/Unset Area 1
3
Area 2
Set/Part Set/Unset Area 2
4
Area 3
Set/Part Set/Unset Area 3
Note: User codes are programmed via a master level code (factory default 5678).
Note: Part Sets will only be available if they have been programmed by the
engineer.
Note: Reset will be available on the code level programmed by the engineer.
In the event that an area does not have a code allocated to it (e.g area 1 code has
been deleted) any other area code setting the system will also set the area without a
code. This is to ensure that no areas can be left unset unintentionally.
Care should be taken by the engineer when allocating part sets so they do not overlap
into other areas.
The cleaner area acts in a different way to other areas. The cleaner area is set up
within the Test/Part/Chime programming sequence. Cleaner zones will then be
removed from the system when a Part/Area 0 is used. The different ways that a
cleaner code operates are:-
With system unset
Cleaner code will fully set the system.
With full system set
Cleaner code will unset only the cleaner zones.
With system part set 0
Cleaner code will set the remainder of the system.
With any one or more
areas set
Cleaner code will set the cleaner zones.
GARDTEC
800 Series
Areas & Zones