![GARDINER TECHNOLOGY Gardtec 800 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/gardiner-technology/gardtec-800/gardtec-800_installation-instructions-manual_3550421040.webp)
Page
77
Page
76
8
M
ISCELLANEOUS
Resetting to Factory Defaults
When resetting the Gardtec
800 Series
to factory defaults several levels of resetting
are available, these are:-
a)
Pressing 1, 9, YES, NO during initial power up will revert the Master Code
and Engineer Code (not locked engineer code) back to factory defaults.
b)
Pressing 3, 7, YES, NO during initial power up will revert all system settings
back to defaults with the exception of the User Names and Zone Descriptors.
c)
Pressing 4, 6, YES, NO during initial power up will revert all system settings
back to factory defaults.
d)
Pressing 5, 5, YES, NO during initial power up will revert all system settings to
factory defaults and will also set the comms options up for Gardtec Remote.
ie Modem On; No Return. For commissioning systems for use with
Gardtec Remote use this option.
To effect a reset of the factory defaults:-
1)
Remove all power from the system for at least ten seconds
2)
Apply power to the control panel (mains power)
the display will show:-
(Display will differ dependant on panel)
3)
Whilst this display is showing (the first eight
seconds) press the keys shown in a, b or c
for the reset required, the display will show:-
This may show for several minutes.
4)
The display will then show:-
Temporary access may be gained to the factory defaults by removing Lk1 on the main
PCB, the link must be replaced before any programming is commenced, this option will
have no effect if the engineer code is locked.
Should the EEprom or E2 be changed on the main PCB we would recommend
that a full reset is carried out (4, 6, YES, NO)
GardTec 840 v 1.0
Please Wait
< < < < UN-SET > > > >
01 Jan 00: 00: 01
GARDTEC
800 Series
Specification & Records
Zone No.
Descriptor
Area(s)
Loop Ohm V @ Sensor
Part Info
93
94
95
96
97
98
Aux Current (mA)
Bell Current (mA)
RKP Current (mA)
Customer Name:-
Contact Name:-
Tel No:-
Fax No:-
Modem No:-
Customer Address:-
Other:-
Service Due Dates
Completed Date
Signature