Fig. 25 Typical 2 Wire EOL Configuration
+ -
12V
+ -
AZ1
+ -
TZ1
+ -
AZ2
+ -
TZ2
+ -
AZ3
+ -
TZ3
+ -
AZ4
+ -
TZ4
+ -
AZ5
+ -
TZ5
+ -
AZ6
+ -
TZ6
+ -
AZ7
+ -
TZ7
+ -
AZ8
+ -
TZ8
ALARM
ZONE 1
+ LOOP
ALARM
ZONE 9
- LOOP
ALARM
ZONE 2
+ LOOP
ALARM
ZONE 10
- LOOP
ALARM
ZONE 3
+ LOOP
ALARM
ZONE 11
- LOOP
ALARM
ZONE 4
+ LOOP
ALARM
ZONE 12
- LOOP
ALARM
ZONE 5
+ LOOP
ALARM
ZONE 13
- LOOP
ALARM
ZONE 6
+ LOOP
ALARM
ZONE 14
- LOOP
ALARM
ZONE 7
+ LOOP
ALARM
ZONE 15
- LOOP
ALARM
ZONE 8
+ LOOP
ALARM
ZONE 16
- LOOP
DETECTOR
SUPPLY
Single Passive Infra-Red
Normally Closed Alarm Pair
Normally Closed Alarm Pair
+ Supply
- Supply
Single Contact
Exit Terminator Button
(if required)
Normally Open Push Button
Normally Open Pressure Pad
(To Detector Supply -ve)
Single Pressure Pad
(Pressure Pads on AZ Zones
Only)
To detector -ve supply
Note:
If exit terminator is required program zone as ET
If unset doorbell is required allocate chime to the
ET zone.
Exit terminator zone must be AZ zone
Setting Mode should be programmed for ET
Note:
Maximum of 10 detectors per loop using EOL
Note:
Resistor Colour Codes Are:-
4K7 = Yellow, Purple, Red with gold tolerance band - EOL Resistor
6K8 = Blue, Grey, Red with gold tolerance band - Bypass Resistor
Note:
All unused zones should have factory fitted link removed
and replaced with the 4K7 EOL Resistor.
It is not advisable to fit normally open devices
onto TZ loops.
6K8
4K7
6K8
4K7
All Normally Closed Contacts
Multiple Contacts
4K7
6K8
6K8
6K8
4K7
6K8
4K7
6K8
Page
36
Zone Connections
(control panel 2 Wire EOL option)
The third wiring method is Two Wire EOL (End Of Line resistor). This option will give
sixteen zones available from the control panel PCB.
To use the 2 wire EOL option the control panel should be programmed for
16 (2 WIRE EOL) in the programming section 'PROGRAM ZONE WIRING' (option
No.50)
When this wiring option is programmed zones AZ1 to AZ8 are zones 1 to 8 inclusive.
Because the 2 wire EOL option has been selected the TZ terminals are also
programmable as zones. The zone numbering for the TZ zones will be as follows:-
Zone 9 on terminals TZ1
Zone 10 on terminals TZ2
Zone 11 on terminals TZ3
Zone 12 on terminals TZ4
Zone 13 on terminals TZ5
Zone 14 on terminals TZ6
Zone 15 on terminals TZ7
Zone 16 on terminals TZ8
Up to 10 detectors may be used on each loop. A 6K8 resistor is connected across the
alarm pair of each detector and a 4K7 resistor is connected in series with the loop at
the furthest most point.
EOL wiring will give the best possible wiring security as it will not allow any bridging or
cutting of the zone loop
Typical wiring of various detectors is given in Figs.25 to 29