GARDTEC
800 Series
Programming
Option No/
Description
Default
Gardtec
800 Series Programming Guide
Available Options
1
Relay Mode
Bell
(00)
As Expander Mode (Option 83)
2
Timer1
Turn On
Time (Hrs)
00
Hours
(00)
00 - 23 Hours
3
Timer1
Turn On
Time (Min)
00
Minutes
(00)
00 - 59 Minutes
4
Timer1
Turn Off
Time (Hrs)
00
Hours
(00)
00 - 23 Hours
5
Timer1
Turn Off
Time (Min)
00
Minutes
(00)
00 - 59 Minutes
6
PA Test
Non-
Testable
(01)
(00) Testable
(01) Non-Testable
Only applies to Test when accessed from Engineer Code
7
PA Mode
Bells
Only
(02)
(00) Silent
(01) Bells if Linefault
(02) Bells Only
(03) Bells Always
8
Chime Level
5
(5)
0 - 9
9
Entry/Exit
Level
5
(5)
0 - 9
10
Part Set
Sounders
Always
Audible
(00)
(00) Always Audible (01) Silent If Part 1
(02) Silent If Part 2
(03) Silent If Part 3 (04) Always Silent
Programming Guide
Due to the vast range of features available on the Gardtec
800 Series
control
panel we strongly advise that an LCD keypad is used for programming.
Note: Throughout this section all reference to settings and defaults applicable to
LED only displays are given within brackets e.g ( ).
6
P
ROGRAMMING
Gardtec
800 Series Programming
To program the Gardtec
800 Series
the engineer must first enter the programming
routine by entering the engineer code (factory default 1234), LCD displays will then
show:-
(LED displays will show ' En ' flashing),
Press YES to enter into the programming routine.
LCD displays will then show:-
(LED displays will show a static ' E - ')
If you are using an LCD keypad two methods may be used to access the various
programmable options.
Method 1
At any point during programming where three underscores are shown in the top right
hand corner of the screen, you may enter the number of the option (given in the
section Quick Programming Guide) you wish to program followed by YES. The
program will then move direct to that option.
Method 2
The programming routine is structured with a series of headers for example:-
This is the header of the Zone programming routine, all zone programming options are
accessed through this header. If you do not wish to program anything under the zone
header pressing NO will move to the next header. For example pressing NO on the
display above will move to the next header shown below:-
Details of the available headers and the options available under each header can be
found in the section Gardtec
800 Series
Program Orders.
Do you want to . .
Use ENGNR. Mode ?
Program . . . . _ _ _
Zones ?
Program . . . . _ _ _
Zones ?
Program . . . . _ _ _
Setting Modes ?
4344R12.qxd 03/09/99 11:09 Page 54