![GARDINER TECHNOLOGY Gardtec 800 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/gardiner-technology/gardtec-800/gardtec-800_installation-instructions-manual_3550421023.webp)
Page
43
Page
42
Expander Card 2 (Jumper in position 2
840
only)
4 Wire Mode
2 Wire Mode
2 Wire EOL Mode
AZE1
Zone 31
Zone 31
Zone 31
AZE2
Zone 32
Zone 32
Zone 32
AZE3
Zone 33
Zone 33
Zone 33
AZE4
Zone 34
Zone 34
Zone 34
TZE1
Tamper Zone 31
Zone 35
Zone 35
TZE2
Tamper Zone 32
Zone 36
Zone 36
TZE3
Tamper Zone 33
Zone 37
Zone 37
TZE4
Tamper Zone 34
Zone 38
Zone 38
Note: All AZE zones are +ve and all TZE zones are -ve.
Expander Card 3 (Jumper in position 3
840
only)
4 Wire Mode
2 Wire Mode
2 Wire EOL Mode
AZE1
Zone 41
Zone 41
Zone 41
AZE2
Zone 42
Zone 42
Zone 42
AZE3
Zone 43
Zone 43
Zone 43
AZE4
Zone 44
Zone 44
Zone 44
TZE1
Tamper Zone 41
Zone 45
Zone 45
TZE2
Tamper Zone 42
Zone 46
Zone 46
TZE3
Tamper Zone 43
Zone 47
Zone 47
TZE4
Tamper Zone 44
Zone 48
Zone 48
Note: All AZE zones are +ve and all TZE zones are -ve.
Expander Card 4 (Jumper in position 4
840
only)
4 Wire Mode
2 Wire Mode
2 Wire EOL Mode
AZE1
Zone 51
Zone 51
Zone 51
AZE2
Zone 52
Zone 52
Zone 52
AZE3
Zone 53
Zone 53
Zone 53
AZE4
Zone 54
Zone 54
Zone 54
TZE1
Tamper Zone 51
Zone 55
Zone 55
TZE2
Tamper Zone 52
Zone 56
Zone 56
TZE3
Tamper Zone 53
Zone 57
Zone 57
TZE4
Tamper Zone 54
Zone 58
Zone 58
Note: All AZE zones are +ve and all TZE zones are -ve.
GARDTEC
800 Series
Wiring Connections
Zone Expander Card Ident & Zone Allocation
Each of the
840
expander cards has eight pairs of ident pins labelled EXP1 to EXP8. It
is essential that the expander cards have the correct ident set. The jumper (supplied
with the unit in position 1) should be moved to the desired ident before the system is
powered up. No two zone expander cards should share the same ident.
As with the control panel zones 3 wiring methods are available for the expander cards.
These are:-
4 Wire
(giving 4 zones and 4 tamper loops per card)
2 Wire
(giving 8 two wire zones per card)
2 Wire EOL
(giving 8 two wire EOL zones per card)
Each expander may be programmed individually (through the control panel) for the
wiring mode you wish to use. Any unused expander cards may be programmed to Off.
To simplify the counting of zones for the Gardtec
840
when expanders are used
the panel should be viewed as unit 1, therefore the first expander becomes unit
2. All zones on unit 2 begin with a 2 (ie.zone 21 is on the second unit as it begins
with a 2). The second expander is unit 3, all zones on unit 3 begin with a 3, and
so on.....
Zones are allocated to each card with respect to the jumper position as follows:-
Expander Card 1 (Jumper in position 1
840
only)
4 Wire Mode
2 Wire Mode
2 Wire EOL Mode
AZE1
Zone 21
Zone 21
Zone 21
AZE2
Zone 22
Zone 22
Zone 22
AZE3
Zone 23
Zone 23
Zone 23
AZE4
Zone 24
Zone 24
Zone 24
TZE1
Tamper Zone 21
Zone 25
Zone 25
TZE2
Tamper Zone 22
Zone 26
Zone 26
TZE3
Tamper Zone 23
Zone 27
Zone 27
TZE4
Tamper Zone 24
Zone 28
Zone 28
Note: All AZE zones are +ve and all TZE zones are -ve.
GARDTEC
800 Series
Wiring Connections
4344R12.qxd 03/09/99 11:09 Page 42