TR-CL180 Lens Controller - User Manual
Add a step to the sequence
RX1,2,f,t
Where:
f
focal power in diopters
t
time at this step in milliseconds
Add a step to the sequence using the current focus
RX1,3,t
Where:
t
= time at this step in milliseconds
Status command
ST
An example of the information that could be returned on receipt of
an
ST
command is given below:
CH1,MD2, AF 0.00, IF 0.00,IP1,FL14
Analog profile: (1.00, -4.00), (1.90, -3.50),
(2.80, -3.20), (3.70, -2.00), (4.6
0, -1.50), (5.40, 1.50), (6.30, 2.00), (7.20,
3.20), (8.10, 3.50), (9.00, 4.00),
Waveform period 0.050s
No EEPROM range IF 0.00 XF 0.00, current IC
0.000 XC 0.000
Step sequence: (4.00, 0.10), (3.00, 0.20),
(2.00, 0.15), (1.00, 0.20), (0.00, 0.
30), (-1.00, 0.10), (-2.00, 0.20), (-3.00,
0.30), (-4.00, 0.15),
Note:
The
analog profile
lists the points entered using the RA
commands, and the
step sequence
lists the points entered using
the RX commands.
—
40
—
WWW.STEMMER-IMAGING.COM