15.4 Error codes
Some error codes are displayed on the TR-CL180’s front panel; these are
shown in red.
Error
number
Reason
Err 1
A parameter value is invalid.
Err 2
Command not recognised.
Err 3
A numeric value is in the wrong format.
Err 4
Wrong number of parameters.
Err 5
This is a warning, not an error. One of the parameters is
out of range and the value of that parameter has been
adjusted.
Err 8, 12
EEPROM corrupt. The configuration has been cleared.
Err 9, 20
Settings could not be saved to EEPROM.
Err 27
Ethernet settings cannot be read from EEPROM. They
may be incorrect.
Err 44
FAt
Fatal error: The TR-CL180 is too hot. The unit has a
thermal cut out which operates at approximately 65°C
to 70°C depending on conditions.
Err 192
Unable to read EEPROM in lens.
Err 193, 194,
195
Lens EEPROM format is wrong.
Err 196
Current required for the optical power by the lens is
more than the lens is rated for or more than the con-
troller can supply.
Err 197
Lens temperature is outside its operating range.
—