TR-CL180 Lens Controller - User Manual
15
TR-CL180 reference information
This section of the user manual contains information about the
TR-CL180’s specification, ratings and restrictions, and event and error
codes.
15.1 Specifications and ratings
TR-CL180
Output
channel
One channel, including constant current lens drive
and lens EEPROM data communications.
Automatically reads data from EEPROM inside lens
which calibrates the controller response. The
performance of the controller is therefore
automatically tailored to each individual lens.
Lens
compatibility
Compatible with Optotune EL-10-30, and EL-16-40
lens ranges. Full current calibration with lens
temperature compensation.
Operating
modes
Single configurable optical power. Two optical
powers, selected by digital input Optical power set
by analog input.
Digital input
Smart input 3V-24V, TTL, NPN, PNP compatible
Analog input
0V to 10V, 7K input impedance Nominal 12-bit
resolution.
Refocus
latency
1ms (not including communications delays).
Output
current
-400mA to +400mA in 0.1mA steps, accuracy
+/- 0.5mA.
Output
voltage
-16V to +16V
User interface
Ethernet (easy to use GUI by means of in-built web
server), RS232, and push button.
Lens
connector
6-way Hirose HR 10 G lens connector
Power supply
24V +/-10%. An SELV power supply is required
Input power 10W maximum
Operating
temperature
5°C to 50°C
—
42
—