WWW.STEMMER-IMAGING.COM
TR-CL180 Lens Controller - User Manual
For example:
RA1,1,4
Set 4 points
RA1,2,0,0.2,2.3
<= 2.3V gives 0.2 diopters
RA1,2,1,4.0,6
6V gives 4.0 diopters
RA1,2,2,7.2,8
≥
8V gives 7.2 diopters
RA1,2,3,1.0,4
4V gives 1.0 diopter
In this example, the point for 4V has been added after the 6V and
8V points. This gives the following relationship:
Note that in this example 5V will give 2.5 diopters.
14.6 Waveform commands
Waveform mode generates a signal with a value from the active focus to
the idle focus.
Single shot waveforms run for one cycle when a trigger input signal is
received. At the end of the cycle the focus is left as the last value of the
waveform.
Continuous waveforms run independently of the trigger signal.
Sawtooth waves default to a slow rise and instant fall.
The waveforms are illustrated overleaf:
—
34
—
WWW.STEMMER-IMAGING.COM