Revision 4
57
12/15/2018
5.3 The Component Table
The
Component Table
consists of three regions:
•
A ribbon which contains controls for the table of chromatographic information and is used to
enter a number of values used in calculations. The nature of the ribbon is dependent on the
selection of the Method. If the ISO method is used, see Section 5.3.1.1 if the GPA or Liquid
method is used, see Section 5.3.1.2. .
•
A table for chromatographic parameters (Section 5.4)
•
A table that displays the calculated physical properties for the calibration gas. (Section 5.5)
5.3.1 The Ribbon
The
Ribbon
(Figure 5-2) is used to add/remove a line from tables, send a configuration to the
chromatograph and enter values required for calculations. Some typical values for all
components are found in the table in Section 14. The format of the ribbon is dependent on
the
Method
that is employed. If the GPA method is used, see Section 5.3.1.1, if the ISO
method is used, see Section 5.3.1.2.
Figure 5-2: The Ribbon (ISO Method)
5.3.1.1 The Ribbon – ISO Method
Add Component
– used to add a line to various tables as described below. The line is
added directly below the line indicated by the ►.
Delete Component
– is used to remove the line in the table indicated by the ►.
Write to Analyzer
– sends the present configuration to the analyzer.
The
Use Helium Fixed Factor
check box should be checked if it is desired to correct the
analytical results for the He concentration in the gas. The Helium concentration is to be
entered in the field below the
Use Unnormalized Concentration
field.
Содержание AccuChrome MA2963
Страница 21: ...Revision 4 8 12 15 2018 Figure 2 7 The Intrinsically Safe Barrier ...
Страница 24: ...Revision 4 11 12 15 2018 Figure 2 10 4 Minute Analysis Flow Diagram ...
Страница 26: ...Revision 4 13 12 15 2018 Figure 3 1 Physical Dimensions Class 1 Div 2 ACCUCHROME Chromatograph ...
Страница 58: ...Revision 4 45 12 15 2018 Figure 4 24 Chart Commands ...
Страница 65: ...Revision 4 52 12 15 2018 A sample report is shown in Figure 4 32 Figure 4 32 Sample Report ...
Страница 80: ...Revision 4 67 12 15 2018 Figure 5 10 Streams Setup ...
Страница 104: ...Revision 4 91 12 15 2018 Figure 8 2 Enron Mode Short Integers ...
Страница 114: ...Revision 4 101 12 15 2018 SS 2F LE MICRON INLINE FILTER HOUSING SS 2F K4 7 7 MICRON INLINE FILTER ELEMENT ...
Страница 124: ...Revision 4 111 12 15 2018 Figure 12 1 PLGC Power Connections Figure 12 2 Relays Wiring Diagram ...
Страница 125: ...Revision 4 112 12 15 2018 Figure 12 3 Analog Outputs Loop Powered Mode Figure 12 4 Analog Outputs Self Powered Mode ...
Страница 126: ...Revision 4 113 12 15 2018 Figure 12 5 Isolated RS 485 Port Connection Figure 12 6 Isolated RS 232 Connections ...
Страница 129: ...Revision 4 116 12 15 2018 Figure 12 11 Oven RTD and TCD Connections Figure 12 12 Arcnet AC485 Twisted Pair Connection ...
Страница 130: ...Revision 4 117 12 15 2018 Figure 12 13 Oven Heater Connection Figure 12 14 GC Valves Connections ...
Страница 131: ...Revision 4 118 12 15 2018 Figure 12 15 Solenoids 5 to 10 Connections Figure 12 16 Solenoids 1 to 4 Connections ...
Страница 132: ...Revision 4 119 12 15 2018 Figure 12 17 Digital Inputs Connections Figure 12 18 Cabinet Heater Connection ...
Страница 139: ...Revision 4 126 12 15 2018 Section 15 Valco 6 and 10 Port Valve Technical Information 15 1 Valve Operation Instructions ...
Страница 140: ...Revision 4 127 12 15 2018 ...
Страница 141: ...Revision 4 128 12 15 2018 15 2 Valve Maintenance Instructions ...
Страница 142: ...Revision 4 129 12 15 2018 ...