Log In/Log Out - Presents the Log in Navigation dialog box (Figure 4-11). When the system is
logged in, the function of this button toggles to Log Off.
Permanent Configuration Write - stores the present configuration on the chromatograph.
Save Configuration - stores the present configuration on the computer
Change Password - presents a dialog box to enter the existing password and the new password.
The new password must be entered two times to verify the correct entry. This dialog box can be
used to change the GUI password.
About - presents a dialog box with the version number and software release date. Please provide
this information when inquiring about service issues.
4.4.3 System Operating Parameters
The left column of the window presents the status of the system and a variety of operating
parameters. These fields are updated once per second and cannot be edited by the
operator.
The top line indicates the GUI connection status: OFFLINE, READ ONLY or UPDATE.
The second line indicates the status of the chromatograph: RUNNING, HALT or HALT
PENDING.
A green stripe at the bottom of this region indicates that data is being transferred, if the
chromatograph is transmitting data to the computer, the Rx indicator will be green. If the,
computer is transmitting data to the chromatograph the Tx indicator will be green. A red light
by Alarms indicates that an alarm was noted (see bottom of window to view it).
4.4.4 Alarm Tab
The
Alarm
tab at the bottom of the window is provided to access the
Alarms
table and
Events
table, which may provide important operating information.
4.4.5 Min and Max Buttons
The
Min
and
Max
buttons are used to select the overall display of the screen. In
Min
mode,.
the Toolbar is presented and the tabbed pages are reduced in size.
Содержание AccuChrome MA2963
Страница 21: ...Revision 4 8 12 15 2018 Figure 2 7 The Intrinsically Safe Barrier ...
Страница 24: ...Revision 4 11 12 15 2018 Figure 2 10 4 Minute Analysis Flow Diagram ...
Страница 26: ...Revision 4 13 12 15 2018 Figure 3 1 Physical Dimensions Class 1 Div 2 ACCUCHROME Chromatograph ...
Страница 58: ...Revision 4 45 12 15 2018 Figure 4 24 Chart Commands ...
Страница 65: ...Revision 4 52 12 15 2018 A sample report is shown in Figure 4 32 Figure 4 32 Sample Report ...
Страница 80: ...Revision 4 67 12 15 2018 Figure 5 10 Streams Setup ...
Страница 104: ...Revision 4 91 12 15 2018 Figure 8 2 Enron Mode Short Integers ...
Страница 114: ...Revision 4 101 12 15 2018 SS 2F LE MICRON INLINE FILTER HOUSING SS 2F K4 7 7 MICRON INLINE FILTER ELEMENT ...
Страница 124: ...Revision 4 111 12 15 2018 Figure 12 1 PLGC Power Connections Figure 12 2 Relays Wiring Diagram ...
Страница 125: ...Revision 4 112 12 15 2018 Figure 12 3 Analog Outputs Loop Powered Mode Figure 12 4 Analog Outputs Self Powered Mode ...
Страница 126: ...Revision 4 113 12 15 2018 Figure 12 5 Isolated RS 485 Port Connection Figure 12 6 Isolated RS 232 Connections ...
Страница 129: ...Revision 4 116 12 15 2018 Figure 12 11 Oven RTD and TCD Connections Figure 12 12 Arcnet AC485 Twisted Pair Connection ...
Страница 130: ...Revision 4 117 12 15 2018 Figure 12 13 Oven Heater Connection Figure 12 14 GC Valves Connections ...
Страница 131: ...Revision 4 118 12 15 2018 Figure 12 15 Solenoids 5 to 10 Connections Figure 12 16 Solenoids 1 to 4 Connections ...
Страница 132: ...Revision 4 119 12 15 2018 Figure 12 17 Digital Inputs Connections Figure 12 18 Cabinet Heater Connection ...
Страница 139: ...Revision 4 126 12 15 2018 Section 15 Valco 6 and 10 Port Valve Technical Information 15 1 Valve Operation Instructions ...
Страница 140: ...Revision 4 127 12 15 2018 ...
Страница 141: ...Revision 4 128 12 15 2018 15 2 Valve Maintenance Instructions ...
Страница 142: ...Revision 4 129 12 15 2018 ...