![Furuno SFD-1010 Скачать руководство пользователя страница 204](http://html1.mh-extra.com/html/furuno/sfd-1010/sfd-1010_operators-manual_2350505204.webp)
3. Select [Timing Adjust] with the arrow keys, then press the
ENTER
key.
The cursor moves to the slider bar on the right side of the menu.
4. Adjust the timing with the arrow keys.
5. Press the
MENU/ESC
key to close [MENU].
5.7.3
How to adjust the main bang
Adjust the main bang suppression level if main bang appears (at the screen center).
Touch control:
1. Press the
MENU/ESC
key to open [MENU].
2. Tap [SCANNER SETUP].
3. Tap [MBS Adjustment].
The cursor moves to the slider bar on the right side of the menu.
4. Drag the slider bar or tap [+] or [-] to adjust the main bang suppression level.
5. Tap [x] on the title bar to close [MENU].
Key control:
1. Press the
MENU/ESC
key to open [MENU].
2. Select [SCANNER SETUP] with the arrow keys, then press the
ENTER
key.
3. Select [MBS Adjustment] with the arrow keys, then press the
ENTER
key.
The cursor moves to the slider bar on the right side of the menu.
4. Adjust the main bang suppression level with the arrow keys.
5. Press the
MENU/ESC
key to close [MENU].
5-20
5
.
INSTALLATION