Key control:
1. Press the
MENU/ESC
key to open [MENU].
2. Select [SCANNER SETUP] with the arrow keys, then press the
ENTER
key.
3. Select [Heading Alignment] with the arrow keys, then press the
ENTER
key.
The cursor moves to the slider bar on the right side of the menu.
4. Set the heading line bearing with the arrow keys.
5. Press the
MENU/ESC
key to close [MENU].
5.7.2
How to adjust the sweep timing
Radar calculates a range to a target by measuring the time required from the moment
the transmitted echo reaches a target to the moment it is received by their radar antenna.
The received echo is displayed on the screen according to the measured time. The
sweep timing of the antenna unit differs depending on the length of the signal cable
between the control unit and the antenna unit. If sweep timing is not adjusted correctly,
the echo of from a "straight" target is not displayed straightly.
Take the following steps to adjust the timing.
Touch control:
1. Press the
MENU/ESC
key to open [MENU].
2. Tap [SCANNER SETUP].
3. Tap [Timing Adjust].
The cursor moves to the slider bar on the right side of the menu.
4. Drag the slider bar or tap [+] or [-] to set the timing.
5. Tap [x] on the title bar to close [MENU].
Key control:
1. Press the
MENU/ESC
key to open [MENU].
2. Select [SCANNER SETUP] with the arrow keys, then press the
ENTER
key.
(1) Center area pulled
inward
(2) Correct
(3) Center area
pushed outward
5-19
5
.
INSTALLATION